Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2018 |
Principal Product | ground beef |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | $10,000,000-$50,000,000 |
# of Employees | 49 |
Plant Area (Sq.Ft.) | 32,230 |
Annual Production | 16,000,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $153,395 | 2,765,750 | kWh | $0.06 |
Electricity Demand | $78,033 | 5,550 | kW-months/year | $14.06 |
Electricity Fees | $19,295 | - | $ | - |
Natural Gas | $26,733 | 3,910 | MMBtu | $6.84 |
TOTAL ENERGY COSTS | $350,045 | |||
RECOMMENDED SAVINGS* | $34,700 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,011 Cost: - |
$115 | 2,075 | - | - | - | - | $896 | 131 | - | - | - | - |
$115 2,075 kWh |
- - kW-months/year |
- - $ |
$896 131 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $880 Cost: $4 |
$592 | 10,680 | $288 | 21 | - | - | - | - | - | - | - | - |
$592 10,680 kWh |
$288 21 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $12,119 Cost: $600 |
- | - | - | - | - | - | - | - | $12,119 | 1,165 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$12,119 1,165 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,230 Cost: $339 |
$2,230 | 40,261 | - | - | - | - | - | - | - | - | - | - |
$2,230 40,261 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,465 Cost: $322 |
$1,465 | 26,451 | - | - | - | - | - | - | - | - | - | - |
$1,465 26,451 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $6,000 Cost: $3,479 |
- | - | - | - | - | - | - | - | - | - | $6,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$6,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $115 Cost: $53 |
$115 | 2,078 | - | - | - | - | - | - | - | - | - | - |
$115 2,078 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $685 Cost: $1,022 |
$460 | 8,299 | $225 | 16 | - | - | - | - | - | - | - | - |
$460 8,299 kWh |
$225 16 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,070 Cost: $2,129 |
$(-45) | (-811) | $(-21) | (-2) | - | - | $1,136 | 166 | - | - | - | - |
$(-45) (-811) kWh |
$(-21) (-2) kW-months/year |
- - $ |
$1,136 166 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,909 Cost: $19,975 |
$5,371 | 96,941 | $2,538 | 181 | - | - | - | - | - | - | - | - |
$5,371 96,941 kWh |
$2,538 181 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $352 Cost: $1,323 |
$234 | 4,232 | $118 | 8 | - | - | - | - | - | - | - | - |
$234 4,232 kWh |
$118 8 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $864 Cost: $4,146 |
- | - | - | - | $864 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$864 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,700 Cost: $33,392 |
$10,537 | 190,206 | $3,148 | 224 | $864 | - | $2,032 | 297 | $12,119 | 1,165 | $6,000 | - | $10,537 190,206 kWh |
$3,148 224 kW-months/year |
$864 - $ |
$2,032 297 MMBtu |
$12,119 1,165 Tgal |
$6,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost |