IAC logo
IAC Assessment: IP0170
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IP0170
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Indiana University-Purdue University
Assessment Year 2023
Principal Product Plastic Film and Sheet
NAICS 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 112
Plant Area (Sq.Ft.) 105,000
Annual Production 8,200,000 Units
Production Hrs. Annual 7,400
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $345,973 9,225,600 kWh $0.04
Electricity Demand $557,491 21,544 kW-months/year $25.88
Electricity Fees $3,600 - $ -
Natural Gas $37,261 3,733 MMBtu $9.98
TOTAL ENERGY COSTS $944,325
RECOMMENDED SAVINGS* $60,667 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$5,367
Cost:
-
$2,776 73,044 $2,591 100 $2,776
73,044
kWh
$2,591
100
kW-months/year
02: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$1,771
Cost:
-
$1,605 42,226 $166 6 $1,605
42,226
kWh
$166
6
kW-months/year
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$14,876
Cost:
$495
$7,494 197,199 $7,382 285 $7,494
197,199
kWh
$7,382
285
kW-months/year
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$6,289
Cost:
$660
- - $6,289 243 -
-
kWh
$6,289
243
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$26,696
Cost:
$4,266
$13,766 362,275 $12,930 500 $13,766
362,275
kWh
$12,930
500
kW-months/year
06: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS Savings:
$590
Cost:
$113
$540 14,200 $50 2 $540
14,200
kWh
$50
2
kW-months/year
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$140
Cost:
$33
$140 3,663 - - $140
3,663
kWh
-
-
kW-months/year
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,620
Cost:
$564
$1,620 42,643 - - $1,620
42,643
kWh
-
-
kW-months/year
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,123
Cost:
$6,636
$3,123 82,184 - - $3,123
82,184
kWh
-
-
kW-months/year
10: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS Savings:
$195
Cost:
$600
$177 4,662 $18 1 $177
4,662
kWh
$18
1
kW-months/year
TOTAL RECOMMENDED Savings:
$60,667
Cost:
$13,367
$31,241 822,096 $29,426 1,137 $31,241
822,096
kWh
$29,426
1,137
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand