Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, Kingsville
Assessment Year 1996
Principal Product Men's slacks
NAICS n/a
SIC 2325 - Men's and Boys' Separate Trousers and Slacks
Sales $10,000,000-$50,000,000
# of Employees 325
Plant Area (Sq.Ft.) 53,000
Annual Production 1,279,491 Pieces
Production Hrs. Annual 2,290
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $150,550 1,934,642 kWh $0.08
Electricity Demand $91,302 6,684 kW-months/year $13.66
Electricity Fees $684 - $ -
TOTAL ENERGY COSTS $255,243
RECOMMENDED SAVINGS* $41,683 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,923
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)
$ kWh $ kW-months/year $ lb
01: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE Savings:
$7,700
Cost:
$60
$7,700 96,131 - - - - $7,700
96,131
kWh
-
-
kW-months/year
-
-
lb
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$5,738
Cost:
$250
$5,446 181,419 $292 21 - - $5,446
181,419
kWh
$292
21
kW-months/year
-
-
lb
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,180
Cost:
$2,767
$1,930 60,375 $3,250 230 - - $1,930
60,375
kWh
$3,250
230
kW-months/year
-
-
lb
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,022
Cost:
$12,000
$3,960 11,137 $62 29 - - $3,960
11,137
kWh
$62
29
kW-months/year
-
-
lb
05: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE Savings:
$2,738
Cost:
$5,000
$2,738 91,442 - - - - $2,738
91,442
kWh
-
-
kW-months/year
-
-
lb
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,578
Cost:
$12
$1,578 49,238 - - - - $1,578
49,238
kWh
-
-
kW-months/year
-
-
lb
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$771
Cost:
$1,800
$234 7,327 $537 38 - - $234
7,327
kWh
$537
38
kW-months/year
-
-
lb
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$758
Cost:
$2,490
$394 12,309 $364 26 - - $394
12,309
kWh
$364
26
kW-months/year
-
-
lb
09: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$491
Cost:
$920
$491 9,379 - - - - $491
9,379
kWh
-
-
kW-months/year
-
-
lb
10: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$12,707
Cost:
$5,023
- - - - $12,707 100,758 -
-
kWh
-
-
kW-months/year
$12,707
100,758
lb
TOTAL RECOMMENDED Savings:
$41,683
Cost:
$30,322
$24,471 518,757 $4,505 344 $12,707 100,758 $24,471
518,757
kWh
$4,505
344
kW-months/year
$12,707
100,758
lb
TOTAL IMPLEMENTED Savings:
$31,923
Cost:
$18,072
$15,065 326,201 $4,151 294 $12,707 100,758 $15,065
326,201
kWh
$4,151
294
kW-months/year
$12,707
100,758
lb
Savings
Cost
$ kWh $ kW-months/year $ lb
Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)