Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Kennesaw State |
---|---|
Assessment Year | 2022 |
Principal Product | Foodservice Warehousing and Distribution |
NAICS | 424410 - General Line Grocery Merchant Wholesalers |
SIC | 5141 - Groceries, General Line |
Sales | $50,000,000-$100,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 447,000 |
Annual Production | 129,547,668 Pounds |
Production Hrs. Annual | 6,600 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $298,055 | 4,554,110 | kWh | $0.07 |
Electricity Demand | $21,375 | 5,700 | kW-months/year | $3.75 |
Electricity Fees | $1,200 | - | $ | - |
Natural Gas | $18,093 | 636 | MMBtu | $28.47 |
TOTAL ENERGY COSTS | $341,007 | |||
RECOMMENDED SAVINGS* | $106,473 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,547 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $8,106 Cost: - |
- | - | $1,494 | 398 | $6,612 | - | - | - |
- - kWh |
$1,494 398 kW-months/year |
$6,612 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS |
Savings: $5,185 Cost: - |
$4,700 | 71,873 | $485 | 129 | - | - | - | - |
$4,700 71,873 kWh |
$485 129 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS |
Savings: $2,067 Cost: $4,835 |
$1,122 | 17,155 | $945 | 252 | - | - | - | - |
$1,122 17,155 kWh |
$945 252 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $2,342 Cost: $3,334 |
$2,171 | 33,196 | $171 | 46 | - | - | - | - |
$2,171 33,196 kWh |
$171 46 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $741 Cost: $390 |
$687 | 10,512 | $54 | 14 | - | - | - | - |
$687 10,512 kWh |
$54 14 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $397 Cost: - |
$357 | 5,457 | $40 | 11 | - | - | - | - |
$357 5,457 kWh |
$40 11 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,386 Cost: $4,602 |
$1,137 | 17,382 | $117 | 31 | - | - | $1,132 | - |
$1,137 17,382 kWh |
$117 31 kW-months/year |
- - $ |
$1,132 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $85,249 Cost: $849,734 |
$81,068 | 1,239,579 | $4,181 | 1,115 | - | - | - | - |
$81,068 1,239,579 kWh |
$4,181 1,115 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $106,473 Cost: $862,895 |
$91,242 | 1,395,154 | $7,487 | 1,996 | $6,612 | - | $1,132 | - | $91,242 1,395,154 kWh |
$7,487 1,996 kW-months/year |
$6,612 - $ |
$1,132 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,547 Cost: $8,559 |
$4,337 | 66,320 | $1,210 | 323 | - | - | - | - | $4,337 66,320 kWh |
$1,210 323 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Administrative Changes |