IAC logo
IAC Assessment: KS2206
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KS2206
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Kennesaw State
Assessment Year 2022
Principal Product Foodservice Warehousing and Distribution
NAICS 424410 - General Line Grocery Merchant Wholesalers
SIC 5141 - Groceries, General Line
Sales $50,000,000-$100,000,000
# of Employees 130
Plant Area (Sq.Ft.) 447,000
Annual Production 129,547,668 Pounds
Production Hrs. Annual 6,600
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $298,055 4,554,110 kWh $0.07
Electricity Demand $21,375 5,700 kW-months/year $3.75
Electricity Fees $1,200 - $ -
Natural Gas $18,093 636 MMBtu $28.47
TOTAL ENERGY COSTS $341,007
RECOMMENDED SAVINGS* $106,473 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,547
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Administrative Changes Electricity Usage Electricity Demand Electricity Fees Administrative Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$8,106
Cost:
-
- - $1,494 398 $6,612 - - - -
-
kWh
$1,494
398
kW-months/year
$6,612
-
$
-
-
$
02: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$5,185
Cost:
-
$4,700 71,873 $485 129 - - - - $4,700
71,873
kWh
$485
129
kW-months/year
-
-
$
-
-
$
03: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$2,067
Cost:
$4,835
$1,122 17,155 $945 252 - - - - $1,122
17,155
kWh
$945
252
kW-months/year
-
-
$
-
-
$
04: 2.2522 ISOLATE HOT OR COLD EQUIPMENT Savings:
$2,342
Cost:
$3,334
$2,171 33,196 $171 46 - - - - $2,171
33,196
kWh
$171
46
kW-months/year
-
-
$
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$741
Cost:
$390
$687 10,512 $54 14 - - - - $687
10,512
kWh
$54
14
kW-months/year
-
-
$
-
-
$
06: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$397
Cost:
-
$357 5,457 $40 11 - - - - $357
5,457
kWh
$40
11
kW-months/year
-
-
$
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,386
Cost:
$4,602
$1,137 17,382 $117 31 - - $1,132 - $1,137
17,382
kWh
$117
31
kW-months/year
-
-
$
$1,132
-
$
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$85,249
Cost:
$849,734
$81,068 1,239,579 $4,181 1,115 - - - - $81,068
1,239,579
kWh
$4,181
1,115
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$106,473
Cost:
$862,895
$91,242 1,395,154 $7,487 1,996 $6,612 - $1,132 - $91,242
1,395,154
kWh
$7,487
1,996
kW-months/year
$6,612
-
$
$1,132
-
$
TOTAL IMPLEMENTED Savings:
$5,547
Cost:
$8,559
$4,337 66,320 $1,210 323 - - - - $4,337
66,320
kWh
$1,210
323
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Administrative Changes Electricity Usage Electricity Demand Electricity Fees Administrative Changes