Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1989
Principal Product FOOD PROCESSING EQUIPMENT
NAICS n/a
SIC 3469 - Metal Stampings, Nec
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 3,000 Pieces
Production Hrs. Annual 4,930
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $63,457 830,891 kWh $0.08
Natural Gas $15,686 3,880 MMBtu $4.04
TOTAL ENERGY COSTS $79,143
RECOMMENDED SAVINGS* $14,963 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,528
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$582
Cost:
$1,068
$582 7,620 - - - - $582
7,620
kWh
-
-
MMBtu
-
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$2,256
Cost:
$3,800
$605 7,913 $901 223 $750 - $605
7,913
kWh
$901
223
MMBtu
$750
-
$
03: 2.7314 REDUCE VENTILATION AIR Savings:
$2,145
Cost:
$400
$493 6,448 $1,652 409 - - $493
6,448
kWh
$1,652
409
MMBtu
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,836
Cost:
$100
$1,836 24,033 - - - - $1,836
24,033
kWh
-
-
MMBtu
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,101
Cost:
$270
$2,101 27,550 - - - - $2,101
27,550
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,179
Cost:
$3,864
$3,179 41,618 - - - - $3,179
41,618
kWh
-
-
MMBtu
-
-
$
07: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$204
Cost:
-
$67 879 $137 34 - - $67
879
kWh
$137
34
MMBtu
-
-
$
08: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$716
Cost:
-
$716 9,379 - - - - $716
9,379
kWh
-
-
MMBtu
-
-
$
09: 2.7441 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH Savings:
$349
Cost:
$358
- - $349 86 - - -
-
kWh
$349
86
MMBtu
-
-
$
10: 2.6214 SHUT OFF PILOTS IN STANDBY EQUIPMENT Savings:
$343
Cost:
-
- - $743 184 $(-400) - -
-
kWh
$743
184
MMBtu
$(-400)
-
$
11: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,252
Cost:
$700
$448 5,862 $804 199 - - $448
5,862
kWh
$804
199
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$14,963
Cost:
$10,560
$10,027 131,302 $4,586 1,135 $350 - $10,027
131,302
kWh
$4,586
1,135
MMBtu
$350
-
$
TOTAL IMPLEMENTED Savings:
$10,528
Cost:
$6,660
$7,586 99,356 $2,942 728 - - $7,586
99,356
kWh
$2,942
728
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes