Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Univ. of Kansas |
---|---|
Assessment Year | 1991 |
Principal Product | IND. AIR COMPRESSORS |
NAICS | n/a |
SIC | 3564 - Blowers And Fans |
Sales | $50,000,000-$100,000,000 |
# of Employees | 204 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 6,120 Pieces |
Production Hrs. Annual | 5,712 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $387,993 | 7,465,416 | kWh | $0.05 |
Natural Gas | $76,770 | 14,411 | MMBtu | $5.33 |
TOTAL ENERGY COSTS | $464,763 | |||
RECOMMENDED SAVINGS* | $108,909 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $108,909 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Administrative Changes | Electricity Usage | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $21,491 Cost: $19,500 |
- | - | $21,491 | 4,032 | - | - |
- - kWh |
$21,491 4,032 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7245 USE DIRECT AIR SUPPLY TO EXHAUST HOODS |
Savings: $15,055 Cost: $18,000 |
$3,137 | 60,375 | $11,918 | 2,236 | - | - |
$3,137 60,375 kWh |
$11,918 2,236 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $12,114 Cost: $27,600 |
$(-838) | (-16,120) | $12,952 | 2,430 | - | - |
$(-838) (-16,120) kWh |
$12,952 2,430 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $9,818 Cost: $3,800 |
- | - | $9,818 | 1,842 | - | - |
- - kWh |
$9,818 1,842 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $22,099 Cost: $22,000 |
$22,099 | 425,264 | - | - | - | - |
$22,099 425,264 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5194 REDESIGN PROCESS |
Savings: $10,585 Cost: $25,200 |
$10,585 | 145,076 | - | - | - | - |
$10,585 145,076 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $5,650 Cost: $17,100 |
$5,650 | 108,734 | - | - | - | - |
$5,650 108,734 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3512 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY |
Savings: $1,112 Cost: - |
$1,112 | 21,395 | - | - | - | - |
$1,112 21,395 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $899 Cost: $1,000 |
$899 | 17,292 | - | - | - | - |
$899 17,292 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $366 Cost: - |
$366 | 7,034 | - | - | - | - |
$366 7,034 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $9,720 Cost: $5,340 |
$(-990) | (-19,050) | - | - | $10,710 | - |
$(-990) (-19,050) kWh |
- - MMBtu |
$10,710 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,909 Cost: $139,540 |
$42,020 | 750,000 | $56,179 | 10,540 | $10,710 | - | $42,020 750,000 kWh |
$56,179 10,540 MMBtu |
$10,710 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $108,909 Cost: $139,540 |
$42,020 | 750,000 | $56,179 | 10,540 | $10,710 | - | $42,020 750,000 kWh |
$56,179 10,540 MMBtu |
$10,710 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Administrative Changes | Electricity Usage | Natural Gas | Administrative Changes |