IAC logo
IAC Assessment: KU0384
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: KU0384
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Univ. of Kansas
Assessment Year 1992
Principal Product CONVEYOR BELT DRYERS
NAICS n/a
SIC 3552 - Textile Machinery
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 4,050 Pieces
Production Hrs. Annual 2,288
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $87,617 763,775 kWh $0.11
Natural Gas $8,491 1,965 MMBtu $4.32
TOTAL ENERGY COSTS $96,108
RECOMMENDED SAVINGS* $12,225 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,096
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$6,255
Cost:
$100
$6,255 - - - - - $6,255
-
kWh
-
-
MMBtu
-
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,424
Cost:
-
$2,891 25,205 $(-467) (-108) - - $2,891
25,205
kWh
$(-467)
(-108)
MMBtu
-
-
$
03: 2.1122 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT Savings:
$1,309
Cost:
$2,000
- - $1,309 303 - - -
-
kWh
$1,309
303
MMBtu
-
-
$
04: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$730
Cost:
$2,200
- - $730 169 - - -
-
kWh
$730
169
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$841
Cost:
$1,794
$841 7,327 - - - - $841
7,327
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$55
Cost:
-
$111 879 - - $(-56) - $111
879
kWh
-
-
MMBtu
$(-56)
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$477
Cost:
$600
$477 3,810 - - - - $477
3,810
kWh
-
-
MMBtu
-
-
$
08: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$134
Cost:
-
$134 1,172 - - - - $134
1,172
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$12,225
Cost:
$6,694
$10,709 38,393 $1,572 364 $(-56) - $10,709
38,393
kWh
$1,572
364
MMBtu
$(-56)
-
$
TOTAL IMPLEMENTED Savings:
$8,096
Cost:
$2,700
$6,843 4,689 $1,309 303 $(-56) - $6,843
4,689
kWh
$1,309
303
MMBtu
$(-56)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes