Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Univ. of Kansas |
---|---|
Assessment Year | 1998 |
Principal Product | plumbing pipe |
NAICS | n/a |
SIC | 3084 - Plastics Pipe |
Sales | $10,000,000-$50,000,000 |
# of Employees | 165 |
Plant Area (Sq.Ft.) | 141,550 |
Annual Production | 7,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $89,903 | 3,184,349 | kWh | $0.03 |
Electricity Demand | $26,928 | 6,444 | kW-months/year | $4.18 |
Natural Gas | $42,070 | 8,494 | MMBtu | $4.95 |
TOTAL ENERGY COSTS | $198,909 | |||
RECOMMENDED SAVINGS* | $53,440 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $49,320 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $24,460 Cost: $29,380 |
- | - | - | - | $24,460 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$24,460 - $ |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,580 Cost: $2,350 |
$3,730 | 133,939 | $850 | 192 | - | - | - | - | - | - | - | - | - | - |
$3,730 133,939 kWh |
$850 192 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,650 Cost: $7,560 |
- | - | - | - | - | - | $2,650 | 535 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,650 535 MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $1,710 Cost: $1,690 |
- | - | - | - | - | - | $890 | 180 | $820 | 545,250 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$890 180 MMBtu |
$820 545,250 Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $1,600 Cost: $3,800 |
- | - | - | - | - | - | $1,600 | 324 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,600 324 MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,110 Cost: $1,750 |
$230 | 8,206 | $50 | 11 | - | - | - | - | - | - | - | - | $830 | - |
$230 8,206 kWh |
$50 11 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - gal |
$830 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,030 Cost: $120 |
- | - | - | - | - | - | $1,030 | 209 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,030 209 MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $890 Cost: - |
- | - | $110 | 25 | - | - | $780 | 96 | - | - | - | - | - | - |
- - kWh |
$110 25 kW-months/year |
- - $ |
$780 96 MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $820 Cost: $1,000 |
- | - | - | - | - | - | $820 | 166 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$820 166 MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $790 Cost: $1,100 |
$790 | 28,429 | - | - | - | - | - | - | - | - | - | - | - | - |
$790 28,429 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $760 Cost: $310 |
$620 | 22,274 | $140 | 32 | - | - | - | - | - | - | - | - | - | - |
$620 22,274 kWh |
$140 32 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $810 Cost: $1,050 |
- | - | - | - | - | - | - | - | - | - | $980 | 32 | $(-170) | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$980 32 gal |
$(-170) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $12,230 Cost: $41,100 |
- | - | - | - | - | - | - | - | - | - | - | - | $12,230 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - gal |
$12,230 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $53,440 Cost: $91,210 |
$5,370 | 192,848 | $1,150 | 260 | $24,460 | - | $7,770 | 1,510 | $820 | 545,250 | $980 | 32 | $12,890 | - | $5,370 192,848 kWh |
$1,150 260 kW-months/year |
$24,460 - $ |
$7,770 1,510 MMBtu |
$820 545,250 Tgal |
$980 32 gal |
$12,890 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $49,320 Cost: $84,670 |
$5,370 | 192,848 | $1,150 | 260 | $24,460 | - | $5,280 | 1,006 | - | - | - | - | $13,060 | - | $5,370 192,848 kWh |
$1,150 260 kW-months/year |
$24,460 - $ |
$5,280 1,006 MMBtu |
- - Tgal |
- - gal |
$13,060 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes |