Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2007 |
Principal Product | Semi Conductor Device Wafers |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $100,000,000-$500,000,000 |
# of Employees | 287 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 152,000 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,638,227 | 59,369,700 | kWh | $0.03 |
Electricity Demand | $626,261 | 98,330 | kW-months/year | $6.37 |
Natural Gas | $1,120,233 | 179,182 | MMBtu | $6.25 |
TOTAL ENERGY COSTS | $3,384,721 | |||
RECOMMENDED SAVINGS* | $181,801 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,674 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS |
Savings: $81,900 Cost: $65,000 |
- | - | - | - | $81,900 | 13,104 |
- - kWh |
- - kW-months/year |
$81,900 13,104 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $67,570 Cost: $67,000 |
$51,668 | 1,845,309 | $15,902 | 2,496 | - | - |
$51,668 1,845,309 kWh |
$15,902 2,496 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,157 Cost: $20,000 |
$6,215 | 221,958 | $1,942 | 305 | - | - |
$6,215 221,958 kWh |
$1,942 305 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,686 Cost: $20,000 |
- | - | - | - | $7,686 | 1,230 |
- - kWh |
- - kW-months/year |
$7,686 1,230 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $7,471 Cost: $800 |
$5,713 | 204,019 | $1,758 | 276 | - | - |
$5,713 204,019 kWh |
$1,758 276 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6226 OPTIMIZE FILTRATION CLEANING / REPLACEMENT TO MINIMIZE AIR RESISTANCE |
Savings: $5,988 Cost: $3,000 |
$4,562 | 162,926 | $1,426 | 224 | - | - |
$4,562 162,926 kWh |
$1,426 224 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE |
Savings: $3,029 Cost: $800 |
$2,316 | 82,716 | $713 | 112 | - | - |
$2,316 82,716 kWh |
$713 112 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $181,801 Cost: $176,600 |
$70,474 | 2,516,928 | $21,741 | 3,413 | $89,586 | 14,334 | $70,474 2,516,928 kWh |
$21,741 3,413 kW-months/year |
$89,586 14,334 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,674 Cost: $23,000 |
$4,562 | 162,926 | $1,426 | 224 | $7,686 | 1,230 | $4,562 162,926 kWh |
$1,426 224 kW-months/year |
$7,686 1,230 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |