Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2008
Principal Product aircraft power inverter
NAICS 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
SIC 3629 - Electrical Industrial Apparatus, Nec
Sales $10,000,000-$50,000,000
# of Employees 174
Plant Area (Sq.Ft.) 48,500
Annual Production 1,000,000 Units
Production Hrs. Annual 2,340
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $134,445 1,211,243 kWh $0.11
Electricity Demand $41,427 4,133 kW-months/year $10.02
Natural Gas $29,092 2,134 MMBtu $13.63
TOTAL ENERGY COSTS $204,964
RECOMMENDED SAVINGS* $110,521 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $26,227
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$40,528
Cost:
$972,000
$40,528 261,986 - - - - - - $40,528
261,986
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$14,519
Cost:
$1,440
$9,547 86,010 $4,972 496 - - - - $9,547
86,010
kWh
$4,972
496
kW-months/year
-
-
$
-
-
MMBtu
03: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT Savings:
$11,082
Cost:
$1,560
$11,082 99,840 - - - - - - $11,082
99,840
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
04: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$10,101
Cost:
$2,730
$10,101 91,000 - - - - - - $10,101
91,000
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$9,907
Cost:
$214
$6,514 58,687 $3,393 339 - - - - $6,514
58,687
kWh
$3,393
339
kW-months/year
-
-
$
-
-
MMBtu
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$8,118
Cost:
$6,000
- - - - - - $8,118 104 -
-
kWh
-
-
kW-months/year
-
-
$
$8,118
104
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$4,895
Cost:
$7,800
$2,877 25,920 $505 50 - - $1,513 111 $2,877
25,920
kWh
$505
50
kW-months/year
-
-
$
$1,513
111
MMBtu
08: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION Savings:
$4,177
Cost:
$3,120
- - $3,006 300 $1,171 - - - -
-
kWh
$3,006
300
kW-months/year
$1,171
-
$
-
-
MMBtu
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$381
Cost:
$180
$381 3,432 - - - - - - $381
3,432
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,813
Cost:
$42,521
$4,246 38,247 $2,567 221 - - - - $4,246
38,247
kWh
$2,567
221
kW-months/year
-
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$110,521
Cost:
$1,037,565
$85,276 665,122 $14,443 1,406 $1,171 - $9,631 215 $85,276
665,122
kWh
$14,443
1,406
kW-months/year
$1,171
-
$
$9,631
215
MMBtu
TOTAL IMPLEMENTED Savings:
$26,227
Cost:
$51,761
$16,670 150,177 $8,044 767 - - $1,513 111 $16,670
150,177
kWh
$8,044
767
kW-months/year
-
-
$
$1,513
111
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas