Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2008 |
Principal Product | aircraft power inverter |
NAICS | 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing |
SIC | 3629 - Electrical Industrial Apparatus, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 174 |
Plant Area (Sq.Ft.) | 48,500 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 2,340 |
Location (State) | NJ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $134,445 | 1,211,243 | kWh | $0.11 |
Electricity Demand | $41,427 | 4,133 | kW-months/year | $10.02 |
Natural Gas | $29,092 | 2,134 | MMBtu | $13.63 |
TOTAL ENERGY COSTS | $204,964 | |||
RECOMMENDED SAVINGS* | $110,521 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,227 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $40,528 Cost: $972,000 |
$40,528 | 261,986 | - | - | - | - | - | - |
$40,528 261,986 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $14,519 Cost: $1,440 |
$9,547 | 86,010 | $4,972 | 496 | - | - | - | - |
$9,547 86,010 kWh |
$4,972 496 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $11,082 Cost: $1,560 |
$11,082 | 99,840 | - | - | - | - | - | - |
$11,082 99,840 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $10,101 Cost: $2,730 |
$10,101 | 91,000 | - | - | - | - | - | - |
$10,101 91,000 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $9,907 Cost: $214 |
$6,514 | 58,687 | $3,393 | 339 | - | - | - | - |
$6,514 58,687 kWh |
$3,393 339 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $8,118 Cost: $6,000 |
- | - | - | - | - | - | $8,118 | 104 |
- - kWh |
- - kW-months/year |
- - $ |
$8,118 104 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $4,895 Cost: $7,800 |
$2,877 | 25,920 | $505 | 50 | - | - | $1,513 | 111 |
$2,877 25,920 kWh |
$505 50 kW-months/year |
- - $ |
$1,513 111 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $4,177 Cost: $3,120 |
- | - | $3,006 | 300 | $1,171 | - | - | - |
- - kWh |
$3,006 300 kW-months/year |
$1,171 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $381 Cost: $180 |
$381 | 3,432 | - | - | - | - | - | - |
$381 3,432 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,813 Cost: $42,521 |
$4,246 | 38,247 | $2,567 | 221 | - | - | - | - |
$4,246 38,247 kWh |
$2,567 221 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $110,521 Cost: $1,037,565 |
$85,276 | 665,122 | $14,443 | 1,406 | $1,171 | - | $9,631 | 215 | $85,276 665,122 kWh |
$14,443 1,406 kW-months/year |
$1,171 - $ |
$9,631 215 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,227 Cost: $51,761 |
$16,670 | 150,177 | $8,044 | 767 | - | - | $1,513 | 111 | $16,670 150,177 kWh |
$8,044 767 kW-months/year |
- - $ |
$1,513 111 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |