Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2010 |
Principal Product | Bottled water |
NAICS | 312112 - Bottled Water Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 63,500 Thousand Gallons |
Production Hrs. Annual | 8,400 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $707,214 | 20,040,062 | kWh | $0.04 |
Electricity Demand | $478,314 | 45,861 | kW-months/year | $10.43 |
Natural Gas | $70,217 | 6,510 | MMBtu | $10.79 |
TOTAL ENERGY COSTS | $1,255,745 | |||
RECOMMENDED SAVINGS* | $132,940 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,555 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $77,015 Cost: $56,771 |
$54,017 | 1,543,384 | $22,998 | 2,205 | - | - | - | - |
$54,017 1,543,384 kWh |
$22,998 2,205 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $22,178 Cost: $100,000 |
$19,831 | 566,625 | $2,347 | 225 | - | - | - | - |
$19,831 566,625 kWh |
$2,347 225 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2223 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF |
Savings: $8,306 Cost: $20,000 |
$4,801 | 137,220 | $3,505 | 336 | - | - | - | - |
$4,801 137,220 kWh |
$3,505 336 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,050 Cost: $2,440 |
$2,929 | 85,047 | $5,121 | 491 | - | - | - | - |
$2,929 85,047 kWh |
$5,121 491 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,536 Cost: $6,000 |
$3,648 | 104,216 | $1,888 | 181 | - | - | - | - |
$3,648 104,216 kWh |
$1,888 181 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $4,726 Cost: $3,900 |
- | - | - | - | - | - | $4,726 | 438 |
- - kWh |
- - kW-months/year |
- - $ |
$4,726 438 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,787 Cost: $4,200 |
$1,838 | 51,965 | $949 | 91 | - | - | - | - |
$1,838 51,965 kWh |
$949 91 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $2,423 Cost: $1,750 |
- | - | - | - | $2,423 | - | - | - |
- - kWh |
- - kW-months/year |
$2,423 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,592 Cost: $12,000 |
$904 | 25,833 | $688 | 66 | - | - | - | - |
$904 25,833 kWh |
$688 66 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $327 Cost: $630 |
$327 | 9,345 | - | - | - | - | - | - |
$327 9,345 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $132,940 Cost: $207,691 |
$88,295 | 2,523,635 | $37,496 | 3,595 | $2,423 | - | $4,726 | 438 | $88,295 2,523,635 kWh |
$37,496 3,595 kW-months/year |
$2,423 - $ |
$4,726 438 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,555 Cost: $103,070 |
$23,087 | 661,017 | $7,468 | 716 | - | - | - | - | $23,087 661,017 kWh |
$7,468 716 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |