Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2010 |
Principal Product | year books |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 3991 - Brooms And Brushes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 365 |
Plant Area (Sq.Ft.) | 68,000 |
Annual Production | 6,700 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $128,980 | 4,213,699 | kWh | $0.03 |
Electricity Demand | $111,886 | 8,563 | kW-months/year | $13.07 |
TOTAL ENERGY COSTS | $240,866 | |||
RECOMMENDED SAVINGS* | $93,651 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,532 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $29,292 Cost: $375,000 |
$7,991 | 257,799 | - | - | $21,301 | - | - | - |
$7,991 257,799 kWh |
- - kW-months/year |
$21,301 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $34,307 Cost: $18,000 |
$20,172 | 650,720 | $14,135 | 1,084 | - | - | - | - |
$20,172 650,720 kWh |
$14,135 1,084 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $10,520 Cost: $66,360 |
$6,662 | 214,905 | $3,858 | 295 | - | - | - | - |
$6,662 214,905 kWh |
$3,858 295 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $5,599 Cost: $3,000 |
- | - | $5,599 | 428 | - | - | - | - |
- - kWh |
$5,599 428 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,849 Cost: $800 |
$1,051 | 33,916 | $798 | 61 | - | - | - | - |
$1,051 33,916 kWh |
$798 61 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,703 Cost: $800 |
$5,111 | 164,903 | $3,592 | 275 | - | - | - | - |
$5,111 164,903 kWh |
$3,592 275 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $697 Cost: $150 |
$697 | 22,530 | - | - | - | - | - | - |
$697 22,530 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,684 Cost: $13,847 |
$1,434 | 46,260 | $1,008 | 77 | - | - | $242 | - |
$1,434 46,260 kWh |
$1,008 77 kW-months/year |
- - $ |
$242 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $93,651 Cost: $477,957 |
$43,118 | 1,391,033 | $28,990 | 2,220 | $21,301 | - | $242 | - | $43,118 1,391,033 kWh |
$28,990 2,220 kW-months/year |
$21,301 - $ |
$242 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,532 Cost: $18,597 |
$8,293 | 267,609 | $10,997 | 841 | - | - | $242 | - | $8,293 267,609 kWh |
$10,997 841 kW-months/year |
- - $ |
$242 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |