IAC logo
IAC Assessment: LE0299
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LE0299
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2010
Principal Product year books
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 3991 - Brooms And Brushes
Sales $50,000,000-$100,000,000
# of Employees 365
Plant Area (Sq.Ft.) 68,000
Annual Production 6,700 Pieces
Production Hrs. Annual 7,200
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $128,980 4,213,699 kWh $0.03
Electricity Demand $111,886 8,563 kW-months/year $13.07
TOTAL ENERGY COSTS $240,866
RECOMMENDED SAVINGS* $93,651 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,532
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$29,292
Cost:
$375,000
$7,991 257,799 - - $21,301 - - - $7,991
257,799
kWh
-
-
kW-months/year
$21,301
-
$
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$34,307
Cost:
$18,000
$20,172 650,720 $14,135 1,084 - - - - $20,172
650,720
kWh
$14,135
1,084
kW-months/year
-
-
$
-
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$10,520
Cost:
$66,360
$6,662 214,905 $3,858 295 - - - - $6,662
214,905
kWh
$3,858
295
kW-months/year
-
-
$
-
-
$
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$5,599
Cost:
$3,000
- - $5,599 428 - - - - -
-
kWh
$5,599
428
kW-months/year
-
-
$
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,849
Cost:
$800
$1,051 33,916 $798 61 - - - - $1,051
33,916
kWh
$798
61
kW-months/year
-
-
$
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$8,703
Cost:
$800
$5,111 164,903 $3,592 275 - - - - $5,111
164,903
kWh
$3,592
275
kW-months/year
-
-
$
-
-
$
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$697
Cost:
$150
$697 22,530 - - - - - - $697
22,530
kWh
-
-
kW-months/year
-
-
$
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,684
Cost:
$13,847
$1,434 46,260 $1,008 77 - - $242 - $1,434
46,260
kWh
$1,008
77
kW-months/year
-
-
$
$242
-
$
TOTAL RECOMMENDED Savings:
$93,651
Cost:
$477,957
$43,118 1,391,033 $28,990 2,220 $21,301 - $242 - $43,118
1,391,033
kWh
$28,990
2,220
kW-months/year
$21,301
-
$
$242
-
$
TOTAL IMPLEMENTED Savings:
$19,532
Cost:
$18,597
$8,293 267,609 $10,997 841 - - $242 - $8,293
267,609
kWh
$10,997
841
kW-months/year
-
-
$
$242
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost