Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2019 |
Principal Product | Wastewater Equipment |
NAICS | 333911 - Pump and Pumping Equipment Manufacturing |
SIC | 3559 - Special Industry Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 47 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 20,000 Units |
Production Hrs. Annual | 3,120 |
Location (State) | NJ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $108,227 | 1,293,130 | kWh | $0.08 |
Electricity Demand | $36,394 | 5,647 | kW-months/year | $6.44 |
Electricity Fees | $24,291 | - | $ | - |
LPG | $49,403 | 2,396 | MMBtu | $20.62 |
Fuel Oil #2 | $117,941 | 7,530 | MMBtu | $15.66 |
TOTAL ENERGY COSTS | $336,256 | |||
RECOMMENDED SAVINGS* | $133,657 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $133,657 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $7,603 Cost: - |
$1,026 | 12,213 | - | - | $6,577 | 420 | - | - |
$1,026 12,213 kWh |
- - kW-months/year |
$6,577 420 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,873 Cost: $6,000 |
- | - | - | - | $5,873 | 375 | - | - |
- - kWh |
- - kW-months/year |
$5,873 375 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,670 Cost: $2,500 |
$1,290 | 15,355 | $380 | 59 | - | - | - | - |
$1,290 15,355 kWh |
$380 59 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,910 Cost: $23,990 |
$9,508 | 113,183 | $2,402 | 373 | - | - | - | - |
$9,508 113,183 kWh |
$2,402 373 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $1,805 Cost: $5,500 |
$1,393 | 16,579 | $412 | 64 | - | - | - | - |
$1,393 16,579 kWh |
$412 64 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $16,879 Cost: $51,500 |
$13,034 | 155,168 | $3,845 | 597 | - | - | - | - |
$13,034 155,168 kWh |
$3,845 597 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $87,917 Cost: $290,000 |
- | - | - | - | - | - | $87,917 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$87,917 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,657 Cost: $379,490 |
$26,251 | 312,498 | $7,039 | 1,093 | $12,450 | 795 | $87,917 | - | $26,251 312,498 kWh |
$7,039 1,093 kW-months/year |
$12,450 795 MMBtu |
$87,917 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $133,657 Cost: $379,490 |
$26,251 | 312,498 | $7,039 | 1,093 | $12,450 | 795 | $87,917 | - | $26,251 312,498 kWh |
$7,039 1,093 kW-months/year |
$12,450 795 MMBtu |
$87,917 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes |