IAC logo
IAC Assessment: LE0484
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LE0484
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Lehigh University
Assessment Year 2019
Principal Product Wastewater Equipment
NAICS 333911 - Pump and Pumping Equipment Manufacturing
SIC 3559 - Special Industry Machinery, Nec
Sales $10,000,000-$50,000,000
# of Employees 47
Plant Area (Sq.Ft.) 120,000
Annual Production 20,000 Units
Production Hrs. Annual 3,120
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $108,227 1,293,130 kWh $0.08
Electricity Demand $36,394 5,647 kW-months/year $6.44
Electricity Fees $24,291 - $ -
LPG $49,403 2,396 MMBtu $20.62
Fuel Oil #2 $117,941 7,530 MMBtu $15.66
TOTAL ENERGY COSTS $336,256
RECOMMENDED SAVINGS* $133,657 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $133,657
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Fuel Oil #2 Administrative Changes Electricity Usage Electricity Demand Fuel Oil #2 Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$7,603
Cost:
-
$1,026 12,213 - - $6,577 420 - - $1,026
12,213
kWh
-
-
kW-months/year
$6,577
420
MMBtu
-
-
$
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,873
Cost:
$6,000
- - - - $5,873 375 - - -
-
kWh
-
-
kW-months/year
$5,873
375
MMBtu
-
-
$
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,670
Cost:
$2,500
$1,290 15,355 $380 59 - - - - $1,290
15,355
kWh
$380
59
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$11,910
Cost:
$23,990
$9,508 113,183 $2,402 373 - - - - $9,508
113,183
kWh
$2,402
373
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$1,805
Cost:
$5,500
$1,393 16,579 $412 64 - - - - $1,393
16,579
kWh
$412
64
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$16,879
Cost:
$51,500
$13,034 155,168 $3,845 597 - - - - $13,034
155,168
kWh
$3,845
597
kW-months/year
-
-
MMBtu
-
-
$
07: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL Savings:
$87,917
Cost:
$290,000
- - - - - - $87,917 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$87,917
-
$
TOTAL RECOMMENDED Savings:
$133,657
Cost:
$379,490
$26,251 312,498 $7,039 1,093 $12,450 795 $87,917 - $26,251
312,498
kWh
$7,039
1,093
kW-months/year
$12,450
795
MMBtu
$87,917
-
$
TOTAL IMPLEMENTED Savings:
$133,657
Cost:
$379,490
$26,251 312,498 $7,039 1,093 $12,450 795 $87,917 - $26,251
312,498
kWh
$7,039
1,093
kW-months/year
$12,450
795
MMBtu
$87,917
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Fuel Oil #2 Administrative Changes Electricity Usage Electricity Demand Fuel Oil #2 Administrative Changes