Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Lehigh University |
---|---|
Assessment Year | 2021 |
Principal Product | Lumber |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $50,000,000-$100,000,000 |
# of Employees | 39 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 100,000 Units |
Production Hrs. Annual | 5,720 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $45,476 | 995,099 | kWh | $0.05 |
Electricity Demand | $17,989 | 4,482 | kW-months/year | $4.01 |
Electricity Fees | $15,312 | - | $ | - |
Natural Gas | $26,629 | 7,783 | MMBtu | $3.42 |
Fuel Oil #2 | $8,321 | 603 | MMBtu | $13.80 |
Other Energy | $3,962 | 235 | MMBtu | $16.86 |
TOTAL ENERGY COSTS | $117,689 | |||
RECOMMENDED SAVINGS* | $16,937 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,197 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Gas | Electricity Usage | Electricity Demand | Fuel Oil #2 | Other Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $824 Cost: $35 |
$672 | 14,619 | $152 | 38 | - | - | - | - |
$672 14,619 kWh |
$152 38 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,197 Cost: $14,875 |
$5,152 | 111,997 | $1,045 | 262 | - | - | - | - |
$5,152 111,997 kWh |
$1,045 262 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,917 Cost: $8,000 |
- | - | - | - | $2,917 | 210 | - | - |
- - kWh |
- - kW-months/year |
$2,917 210 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $2,375 Cost: $7,600 |
- | - | - | - | $2,375 | 171 | - | - |
- - kWh |
- - kW-months/year |
$2,375 171 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $289 Cost: $1,000 |
$245 | 5,317 | $44 | 11 | - | - | - | - |
$245 5,317 kWh |
$44 11 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,092 Cost: $12,000 |
$2,593 | 56,365 | $499 | 125 | - | - | - | - |
$2,593 56,365 kWh |
$499 125 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $1,243 Cost: $6,000 |
- | - | - | - | $827 | 72 | $416 | 28 |
- - kWh |
- - kW-months/year |
$827 72 MMBtu |
$416 28 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $16,937 Cost: $49,510 |
$8,662 | 188,298 | $1,740 | 436 | $6,119 | 453 | $416 | 28 | $8,662 188,298 kWh |
$1,740 436 kW-months/year |
$6,119 453 MMBtu |
$416 28 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,197 Cost: $14,875 |
$5,152 | 111,997 | $1,045 | 262 | - | - | - | - | $5,152 111,997 kWh |
$1,045 262 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||