Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2001 |
Principal Product | Steel castings |
NAICS | n/a |
SIC | 3312 - Blast Furnaces And Steel Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 135 |
Plant Area (Sq.Ft.) | 212,000 |
Annual Production | 4,800 Tons |
Production Hrs. Annual | 2,400 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $701,322 | 10,284,101 | kWh | $0.07 |
Electricity Demand | $289,201 | 141,573 | kW-months/year | $2.04 |
Electricity Fees | $10,583 | - | $ | - |
Natural Gas | $782,501 | 163,670 | MMBtu | $4.78 |
TOTAL ENERGY COSTS | $1,856,624 | |||
RECOMMENDED SAVINGS* | $156,456 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $111,785 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $22,921 Cost: $4,950 |
$22,039 | 323,917 | - | - | $882 | - | - | - | - | - |
$22,039 323,917 kWh |
- - kW-months/year |
$882 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $36,284 Cost: $19,204 |
- | - | - | - | - | - | $36,284 | 7,314 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$36,284 7,314 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $8,387 Cost: $13,894 |
$6,448 | 132,000 | $1,616 | 792 | $323 | - | - | - | - | - |
$6,448 132,000 kWh |
$1,616 792 kW-months/year |
$323 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $45,054 Cost: $173,974 |
- | - | $43,321 | 21,236 | $1,733 | - | - | - | - | - |
- - kWh |
$43,321 21,236 kW-months/year |
$1,733 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $43,810 Cost: - |
- | - | - | - | - | - | - | - | $43,810 | 3,240 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$43,810 3,240 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $156,456 Cost: $212,022 |
$28,487 | 455,917 | $44,937 | 22,028 | $2,938 | - | $36,284 | 7,314 | $43,810 | 3,240 | $28,487 455,917 kWh |
$44,937 22,028 kW-months/year |
$2,938 - $ |
$36,284 7,314 MMBtu |
$43,810 3,240 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $111,785 Cost: $178,924 |
$22,039 | 323,917 | $43,321 | 21,236 | $2,615 | - | - | - | $43,810 | 3,240 | $22,039 323,917 kWh |
$43,321 21,236 kW-months/year |
$2,615 - $ |
- - MMBtu |
$43,810 3,240 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |