Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: LL0124
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: LL0124
IAC Center University of Louisiana, Lafayette
Assessment Year 2001
Principal Product Valves
NAICS n/a
SIC 3533 - Oil And Gas Field Machinery
Sales $95,000,000
# of Employees 371
Plant Area (Sq.Ft.) 180,000
Annual Production 25,000 Pieces
Production Hrs. Annual 4,160
Location (State) LA
View Case Study
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,128,028 19,758,000 kWh $0.06
Electricity Demand $307,208 41,797 kW/month $7.35
Electricity Fees $51,409 - $ -
Natural Gas $70,204 18,764 MMBtu $3.74
TOTAL ENERGY COSTS $1,640,323
RECOMMENDED SAVINGS* $801,101 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $801,101
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Fuel Oil #1 Other Liquid (non-haz) Electricity Usage Electricity Demand Electricity Fees Fuel Oil #1 Other Liquid (non-haz)
$ kWh $ kW/month $ $ $ MMBtu $ gal
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$537,467
Cost:
$121,200
$516,796 9,034,889 - - $20,671 - - - - - $516,796
9,034,889
kWh
-
-
kW/month
$20,671
-
$
-
-
MMBtu
-
-
gal
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$126,949
Cost:
$31,740
$122,066 2,134,022 - - $4,883 - - - - - $122,066
2,134,022
kWh
-
-
kW/month
$4,883
-
$
-
-
MMBtu
-
-
gal
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$4,948
Cost:
$406
$3,472 60,703 $1,286 175 $190 - - - - - $3,472
60,703
kWh
$1,286
175
kW/month
$190
-
$
-
-
MMBtu
-
-
gal
04: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,399
Cost:
$203
$1,682 29,403 $625 85 $92 - - - - - $1,682
29,403
kWh
$625
85
kW/month
$92
-
$
-
-
MMBtu
-
-
gal
05: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$45,864
Cost:
$112,325
- - $44,100 6,000 $1,764 - - - - - -
-
kWh
$44,100
6,000
kW/month
$1,764
-
$
-
-
MMBtu
-
-
gal
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$83,474
Cost:
$92,279
- - - - - - $26,474 1,430 $57,000 150,000 -
-
kWh
-
-
kW/month
-
-
$
$26,474
1,430
MMBtu
$57,000
150,000
gal
TOTAL RECOMMENDED Savings:
$801,101
Cost:
$358,153
$644,016 11,259,017 $46,011 6,260 $27,600 - $26,474 1,430 $57,000 150,000 $644,016
11,259,017
kWh
$46,011
6,260
kW/month
$27,600
-
$
$26,474
1,430
MMBtu
$57,000
150,000
gal
TOTAL IMPLEMENTED Savings:
$801,101
Cost:
$358,153
$644,016 11,259,017 $46,011 6,260 $27,600 - $26,474 1,430 $57,000 150,000 $644,016
11,259,017
kWh
$46,011
6,260
kW/month
$27,600
-
$
$26,474
1,430
MMBtu
$57,000
150,000
gal
Savings
Cost
$ kWh $ kW/month $ $ $ MMBtu $ gal
Electricity Usage Electricity Demand Electricity Fees Fuel Oil #1 Other Liquid (non-haz) Electricity Usage Electricity Demand Electricity Fees Fuel Oil #1 Other Liquid (non-haz)