Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2002 |
Principal Product | Ceramic Pellets |
NAICS | n/a |
SIC | 3299 - Nonmetallic Mineral Products, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 174,239 |
Annual Production | 100,000,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $533,794 | 12,263,962 | kWh | $0.04 |
Electricity Demand | $153,945 | 20,810 | kW-months/year | $7.40 |
Electricity Fees | $28,799 | - | $ | - |
Natural Gas | $1,178,453 | 199,986 | MMBtu | $5.89 |
TOTAL ENERGY COSTS | $1,934,577 | |||
RECOMMENDED SAVINGS* | $302,147 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $269,865 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1125 CONVERT TO OXYFUEL BURNERS |
Savings: $235,855 Cost: $281,796 |
- | - | - | - | - | - | $235,855 | 39,997 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$235,855 39,997 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $20,887 Cost: $93,094 |
$20,083 | 441,869 | - | - | $804 | - | - | - | - | - |
$20,083 441,869 kWh |
- - kW-months/year |
$804 - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $32,031 Cost: $38,570 |
- | - | $30,799 | 4,162 | $1,232 | - | - | - | - | - |
- - kWh |
$30,799 4,162 kW-months/year |
$1,232 - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $251 Cost: $128 |
- | - | $81 | 11 | $10 | - | $160 | 3,520 | - | - |
- - kWh |
$81 11 kW-months/year |
$10 - $ |
$160 3,520 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $13,123 Cost: - |
- | - | - | - | - | - | - | - | $13,123 | 4,081,768 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$13,123 4,081,768 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $302,147 Cost: $413,588 |
$20,083 | 441,869 | $30,880 | 4,173 | $2,046 | - | $236,015 | 43,517 | $13,123 | 4,081,768 | $20,083 441,869 kWh |
$30,880 4,173 kW-months/year |
$2,046 - $ |
$236,015 43,517 MMBtu |
$13,123 4,081,768 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $269,865 Cost: $374,890 |
$20,083 | 441,869 | - | - | $804 | - | $235,855 | 39,997 | $13,123 | 4,081,768 | $20,083 441,869 kWh |
- - kW-months/year |
$804 - $ |
$235,855 39,997 MMBtu |
$13,123 4,081,768 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal |