IAC logo
IAC Assessment: LL0161
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0161
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2003
Principal Product Oil field equipment
NAICS 333132 - Oil and Gas Field Machinery and Equipment Manufacturing
SIC 3533 - Oil And Gas Field Machinery
Sales $5,000,000-$10,000,000
# of Employees 80
Plant Area (Sq.Ft.) 28,720
Annual Production 9,000 Pieces
Production Hrs. Annual 8,736
Location (State)
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $21,226 344,401 kWh $0.06
Electricity Demand $945 236 kW-months/year $4.00
Electricity Fees $887 - $ -
Natural Gas $4,297 441 MMBtu $9.74
TOTAL ENERGY COSTS $27,355
RECOMMENDED SAVINGS* $12,678 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,514
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas By-product Production Electricity Usage Electricity Demand Electricity Fees Natural Gas By-product Production
$ kWh $ kW-months/year $ $ $ MMBtu $ $
01: 2.7134 USE PHOTOCELL CONTROLS Savings:
$6,194
Cost:
$328
$5,956 96,271 - - $238 - - - - - $5,956
96,271
kWh
-
-
kW-months/year
$238
-
$
-
-
MMBtu
-
-
$
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$1,952
Cost:
$2,121
- - - - - - $1,952 197 - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,952
197
MMBtu
-
-
$
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$1,921
Cost:
$192
$1,847 29,848 - - $74 - - - - - $1,847
29,848
kWh
-
-
kW-months/year
$74
-
$
-
-
MMBtu
-
-
$
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$1,034
Cost:
$763
- - - - - - $1,034 104 - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,034
104
MMBtu
-
-
$
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$641
Cost:
$20
- 9,840 $609 48 $32 - - - - - -
9,840
kWh
$609
48
kW-months/year
$32
-
$
-
-
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$534
Cost:
$520
$513 8,298 - - $21 - - - - - $513
8,298
kWh
-
-
kW-months/year
$21
-
$
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$402
Cost:
$210
$144 2,330 $12 3 $6 - - - $240 - $144
2,330
kWh
$12
3
kW-months/year
$6
-
$
-
-
MMBtu
$240
-
$
TOTAL RECOMMENDED Savings:
$12,678
Cost:
$4,154
$8,460 146,587 $621 51 $371 - $2,986 301 $240 - $8,460
146,587
kWh
$621
51
kW-months/year
$371
-
$
$2,986
301
MMBtu
$240
-
$
TOTAL IMPLEMENTED Savings:
$4,514
Cost:
$2,333
$1,847 39,688 $609 48 $106 - $1,952 197 - - $1,847
39,688
kWh
$609
48
kW-months/year
$106
-
$
$1,952
197
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas By-product Production Electricity Usage Electricity Demand Electricity Fees Natural Gas By-product Production