Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2003 |
Principal Product | Flow control valves |
NAICS | 324110 - Petroleum Refineries |
SIC | 2911 - Petroleum Refining |
Sales | $5,000,000-$10,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 30,000 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $33,220 | 675,400 | kWh | $0.05 |
Electricity Demand | $14,972 | 2,664 | kW-months/year | $5.62 |
Electricity Fees | $2,516 | - | $ | - |
Natural Gas | $79 | 11 | MMBtu | $7.18 |
TOTAL ENERGY COSTS | $50,787 | |||
RECOMMENDED SAVINGS* | $16,640 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $10,856 Cost: $4,436 |
$10,319 | 209,788 | - | - | $537 | - | - | - | - | - |
$10,319 209,788 kWh |
- - kW-months/year |
$537 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $1,828 Cost: $770 |
$1,738 | 35,332 | - | - | $90 | - | - | - | - | - |
$1,738 35,332 kWh |
- - kW-months/year |
$90 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,184 Cost: $345 |
$653 | 13,279 | $472 | 84 | $59 | - | - | - | - | - |
$653 13,279 kWh |
$472 84 kW-months/year |
$59 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $599 Cost: $158 |
$569 | 11,574 | - | - | $30 | - | - | - | - | - |
$569 11,574 kWh |
- - kW-months/year |
$30 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $583 Cost: $560 |
$554 | 11,258 | - | - | $29 | - | - | - | - | - |
$554 11,258 kWh |
- - kW-months/year |
$29 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $474 Cost: $15 |
$277 | 5,639 | $174 | 31 | $23 | - | - | - | - | - |
$277 5,639 kWh |
$174 31 kW-months/year |
$23 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $439 Cost: $598 |
$417 | 8,481 | - | - | $22 | - | - | - | - | - |
$417 8,481 kWh |
- - kW-months/year |
$22 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $571 Cost: $420 |
$197 | 3,995 | - | - | $10 | - | $218 | - | $146 | - |
$197 3,995 kWh |
- - kW-months/year |
$10 - $ |
$218 - $ |
$146 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $106 Cost: $130 |
$101 | 2,053 | - | - | $5 | - | - | - | - | - |
$101 2,053 kWh |
- - kW-months/year |
$5 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $16,640 Cost: $7,432 |
$14,825 | 301,399 | $646 | 115 | $805 | - | $218 | - | $146 | - | $14,825 301,399 kWh |
$646 115 kW-months/year |
$805 - $ |
$218 - $ |
$146 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost |