IAC logo
IAC Assessment: LL0181
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0181
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2004
Principal Product Gas Compressors
NAICS 326122 - Plastics Pipe and Pipe Fitting Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 90
Plant Area (Sq.Ft.) 50,000
Annual Production 200 Pieces
Production Hrs. Annual 4,940
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $87,796 1,285,998 kWh $0.07
Electricity Fees $3,424 - $ -
Natural Gas $37,085 3,472 MMBtu $10.68
TOTAL ENERGY COSTS $128,305
RECOMMENDED SAVINGS* $15,081 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,903
#|Description Savings
Cost
Status Electricity Usage Electricity Fees Natural Gas Ancillary Material Cost Electricity Usage Electricity Fees Natural Gas Ancillary Material Cost
$ kWh $ $ $ MMBtu $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$3,934
Cost:
$395
$3,786 55,462 $148 - - - - - $3,786
55,462
kWh
$148
-
$
-
-
MMBtu
-
-
$
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$3,194
Cost:
$1,013
- - - - $3,194 299 - - -
-
kWh
-
-
$
$3,194
299
MMBtu
-
-
$
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,927
Cost:
$1,805
- - - - $2,927 274 - - -
-
kWh
-
-
$
$2,927
274
MMBtu
-
-
$
04: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,594
Cost:
$420
$2,497 36,574 $97 - - - - - $2,497
36,574
kWh
$97
-
$
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,565
Cost:
$1,015
$659 9,654 $26 - - - $880 - $659
9,654
kWh
$26
-
$
-
-
MMBtu
$880
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$657
Cost:
$135
$632 9,251 $25 - - - - - $632
9,251
kWh
$25
-
$
-
-
MMBtu
-
-
$
07: 4.6110 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$210
Cost:
$165
- - - - - - $210 - -
-
kWh
-
-
$
-
-
MMBtu
$210
-
$
TOTAL RECOMMENDED Savings:
$15,081
Cost:
$4,948
$7,574 110,941 $296 - $6,121 573 $1,090 - $7,574
110,941
kWh
$296
-
$
$6,121
573
MMBtu
$1,090
-
$
TOTAL IMPLEMENTED Savings:
$8,903
Cost:
$2,588
$4,445 65,116 $174 - $3,194 299 $1,090 - $4,445
65,116
kWh
$174
-
$
$3,194
299
MMBtu
$1,090
-
$
Savings
Cost
$ kWh $ $ $ MMBtu $ $
Electricity Usage Electricity Fees Natural Gas Ancillary Material Cost Electricity Usage Electricity Fees Natural Gas Ancillary Material Cost