IAC logo
IAC Assessment: LL0185
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0185
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2004
Principal Product Control Boxes
NAICS 335314 - Relay and Industrial Control Manufacturing
SIC 3625 - Relays And Industrial Controls
Sales $50,000,000-$100,000,000
# of Employees 75
Plant Area (Sq.Ft.) 49,200
Annual Production 1,000 Pieces
Production Hrs. Annual 3,120
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $77,828 1,198,488 kWh $0.06
Electricity Demand $11,875 3,699 kW-months/year $3.21
Electricity Fees $3,473 - $ -
Natural Gas $50,968 7,553 MMBtu $6.75
TOTAL ENERGY COSTS $144,144
RECOMMENDED SAVINGS* $15,988 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,454
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $ $ $
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$5,280
Cost:
$9,967
$5,082 78,250 - - $198 - - - - - $5,082
78,250
kWh
-
-
kW-months/year
$198
-
$
-
-
$
-
-
$
02: 2.8123 PAY UTILITY BILLS ON TIME Savings:
$3,954
Cost:
$30
- - - - $3,954 - - - - - -
-
kWh
-
-
kW-months/year
$3,954
-
$
-
-
$
-
-
$
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,594
Cost:
$1,720
$1,534 23,626 - - $60 - - - - - $1,534
23,626
kWh
-
-
kW-months/year
$60
-
$
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,196
Cost:
$770
$476 7,323 $32 10 $20 - - - $668 - $476
7,323
kWh
$32
10
kW-months/year
$20
-
$
-
-
$
$668
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,041
Cost:
$495
$1,002 15,433 - - $39 - - - - - $1,002
15,433
kWh
-
-
kW-months/year
$39
-
$
-
-
$
-
-
$
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$959
Cost:
$248
$737 11,356 $186 58 $36 - - - - - $737
11,356
kWh
$186
58
kW-months/year
$36
-
$
-
-
$
-
-
$
07: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$363
Cost:
$288
$349 5,376 - - $14 - - - - - $349
5,376
kWh
-
-
kW-months/year
$14
-
$
-
-
$
-
-
$
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$101
Cost:
$56
$97 1,496 - - $4 - - - - - $97
1,496
kWh
-
-
kW-months/year
$4
-
$
-
-
$
-
-
$
09: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$1,500
Cost:
$60
- - - - - - $1,500 - - - -
-
kWh
-
-
kW-months/year
-
-
$
$1,500
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$15,988
Cost:
$13,634
$9,277 142,860 $218 68 $4,325 - $1,500 - $668 - $9,277
142,860
kWh
$218
68
kW-months/year
$4,325
-
$
$1,500
-
$
$668
-
$
TOTAL IMPLEMENTED Savings:
$5,454
Cost:
$90
- - - - $3,954 - $1,500 - - - -
-
kWh
-
-
kW-months/year
$3,954
-
$
$1,500
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes Ancillary Material Cost