Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2004 |
Principal Product | Control Boxes |
NAICS | 335314 - Relay and Industrial Control Manufacturing |
SIC | 3625 - Relays And Industrial Controls |
Sales | $50,000,000-$100,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 49,200 |
Annual Production | 1,000 Pieces |
Production Hrs. Annual | 3,120 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $77,828 | 1,198,488 | kWh | $0.06 |
Electricity Demand | $11,875 | 3,699 | kW-months/year | $3.21 |
Electricity Fees | $3,473 | - | $ | - |
Natural Gas | $50,968 | 7,553 | MMBtu | $6.75 |
TOTAL ENERGY COSTS | $144,144 | |||
RECOMMENDED SAVINGS* | $15,988 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,454 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $5,280 Cost: $9,967 |
$5,082 | 78,250 | - | - | $198 | - | - | - | - | - |
$5,082 78,250 kWh |
- - kW-months/year |
$198 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $3,954 Cost: $30 |
- | - | - | - | $3,954 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,954 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,594 Cost: $1,720 |
$1,534 | 23,626 | - | - | $60 | - | - | - | - | - |
$1,534 23,626 kWh |
- - kW-months/year |
$60 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,196 Cost: $770 |
$476 | 7,323 | $32 | 10 | $20 | - | - | - | $668 | - |
$476 7,323 kWh |
$32 10 kW-months/year |
$20 - $ |
- - $ |
$668 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,041 Cost: $495 |
$1,002 | 15,433 | - | - | $39 | - | - | - | - | - |
$1,002 15,433 kWh |
- - kW-months/year |
$39 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $959 Cost: $248 |
$737 | 11,356 | $186 | 58 | $36 | - | - | - | - | - |
$737 11,356 kWh |
$186 58 kW-months/year |
$36 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $363 Cost: $288 |
$349 | 5,376 | - | - | $14 | - | - | - | - | - |
$349 5,376 kWh |
- - kW-months/year |
$14 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $101 Cost: $56 |
$97 | 1,496 | - | - | $4 | - | - | - | - | - |
$97 1,496 kWh |
- - kW-months/year |
$4 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,500 Cost: $60 |
- | - | - | - | - | - | $1,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,500 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,988 Cost: $13,634 |
$9,277 | 142,860 | $218 | 68 | $4,325 | - | $1,500 | - | $668 | - | $9,277 142,860 kWh |
$218 68 kW-months/year |
$4,325 - $ |
$1,500 - $ |
$668 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,454 Cost: $90 |
- | - | - | - | $3,954 | - | $1,500 | - | - | - | - - kWh |
- - kW-months/year |
$3,954 - $ |
$1,500 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost |