Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2004 |
Principal Product | Oil and Gas field equipment |
NAICS | 333132 - Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3441 - Fabricated Structural Metal |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 190,000 |
Annual Production | 36 Pieces |
Production Hrs. Annual | 5,720 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $362,945 | 6,209,488 | kWh | $0.06 |
Electricity Demand | $112,271 | 22,324 | kW-months/year | $5.03 |
Electricity Fees | $23,470 | - | $ | - |
Natural Gas | $25,959 | 4,150 | MMBtu | $6.26 |
TOTAL ENERGY COSTS | $524,645 | |||
RECOMMENDED SAVINGS* | $74,451 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $42,847 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $16,554 Cost: $30,485 |
- | - | $15,781 | 3,128 | $773 | - | - | - | - | - | - | - |
- - kWh |
$15,781 3,128 kW-months/year |
$773 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $14,949 Cost: $8,940 |
$12,079 | 206,660 | $2,172 | 430 | $698 | - | - | - | - | - | - | - |
$12,079 206,660 kWh |
$2,172 430 kW-months/year |
$698 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $11,938 Cost: $330 |
$11,380 | 194,700 | - | - | $558 | - | - | - | - | - | - | - |
$11,380 194,700 kWh |
- - kW-months/year |
$558 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $10,711 Cost: $15,908 |
- | - | - | - | - | - | $10,711 | 1,650 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$10,711 1,650 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $8,568 Cost: $1,430 |
- | - | - | - | - | - | $8,568 | 1,320 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,568 1,320 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,506 Cost: $42,903 |
$8,109 | 138,737 | - | - | $397 | - | - | - | - | - | - | - |
$8,109 138,737 kWh |
- - kW-months/year |
$397 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $387 Cost: $305 |
$195 | 3,329 | - | - | $10 | - | - | - | $182 | - | - | - |
$195 3,329 kWh |
- - kW-months/year |
$10 - $ |
- - MMBtu |
$182 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $2,500 Cost: $60 |
- | - | - | - | - | - | - | - | - | - | $2,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8112 COMBINE UTILITY METERS |
Savings: $338 Cost: $60 |
$338 | - | - | - | - | - | - | - | - | - | - | - |
$338 - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $74,451 Cost: $100,421 |
$32,101 | 543,426 | $17,953 | 3,558 | $2,436 | - | $19,279 | 2,970 | $182 | - | $2,500 | - | $32,101 543,426 kWh |
$17,953 3,558 kW-months/year |
$2,436 - $ |
$19,279 2,970 MMBtu |
$182 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $42,847 Cost: $82,448 |
$20,526 | 345,397 | $17,953 | 3,558 | $1,868 | - | - | - | - | - | $2,500 | - | $20,526 345,397 kWh |
$17,953 3,558 kW-months/year |
$1,868 - $ |
- - MMBtu |
- - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost |