Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2004 |
Principal Product | ship and repair |
NAICS | 336611 - Ship Building and Repairing |
SIC | 3731 - Ship Building And Repairing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 85,000 |
Annual Production | 10 Pieces |
Production Hrs. Annual | 2,340 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $236,316 | 3,765,560 | kWh | $0.06 |
Electricity Demand | $39,436 | 19,717 | kW-months/year | $2.00 |
Electricity Fees | $7,833 | - | $ | - |
TOTAL ENERGY COSTS | $283,585 | |||
RECOMMENDED SAVINGS* | $154,359 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $138,083 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $107,401 Cost: $19,500 |
$104,476 | 1,664,687 | - | - | $2,925 | - | - | - | - | - |
$104,476 1,664,687 kWh |
- - kW-months/year |
$2,925 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,303 Cost: $12,640 |
$12,941 | 206,197 | - | - | $362 | - | - | - | - | - |
$12,941 206,197 kWh |
- - kW-months/year |
$362 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $8,552 Cost: $882 |
$8,319 | 132,560 | - | - | $233 | - | - | - | - | - |
$8,319 132,560 kWh |
- - kW-months/year |
$233 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,124 Cost: $30 |
$5,957 | 94,924 | - | - | $167 | - | - | - | - | - |
$5,957 94,924 kWh |
- - kW-months/year |
$167 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,679 Cost: $489 |
$1,405 | 22,391 | $228 | 114 | $46 | - | - | - | - | - |
$1,405 22,391 kWh |
$228 114 kW-months/year |
$46 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,024 Cost: $1,080 |
$996 | 15,878 | - | - | $28 | - | - | - | - | - |
$996 15,878 kWh |
- - kW-months/year |
$28 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $557 Cost: $990 |
$542 | 8,641 | - | - | $15 | - | - | - | - | - |
$542 8,641 kWh |
- - kW-months/year |
$15 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $519 Cost: $350 |
$209 | 3,329 | - | - | $6 | - | $304 | - | - | - |
$209 3,329 kWh |
- - kW-months/year |
$6 - $ |
$304 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $15,200 Cost: $2,100 |
- | - | - | - | - | - | $10,200 | - | $5,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$10,200 - $ |
$5,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $154,359 Cost: $38,061 |
$134,845 | 2,148,607 | $228 | 114 | $3,782 | - | $10,504 | - | $5,000 | - | $134,845 2,148,607 kWh |
$228 114 kW-months/year |
$3,782 - $ |
$10,504 - $ |
$5,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $138,083 Cost: $34,621 |
$134,094 | 2,136,637 | $228 | 114 | $3,761 | - | - | - | - | - | $134,094 2,136,637 kWh |
$228 114 kW-months/year |
$3,761 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost |