IAC logo
IAC Assessment: LL0211
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0211
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2004
Principal Product ship and repair
NAICS 336611 - Ship Building and Repairing
SIC 3731 - Ship Building And Repairing
Sales $5,000,000-$10,000,000
# of Employees 40
Plant Area (Sq.Ft.) 60,000
Annual Production 54 Pieces
Production Hrs. Annual 3,510
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $85,501 1,473,546 kWh $0.06
Electricity Demand $25,765 8,441 kW-months/year $3.05
Electricity Fees $3,815 - $ -
TOTAL ENERGY COSTS $115,081
RECOMMENDED SAVINGS* $16,461 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,428
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$4,929
Cost:
$825
$3,805 65,578 $972 168 $152 - - - - - $3,805
65,578
kWh
$972
168
kW-months/year
$152
-
$
-
-
$
-
-
$
02: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT Savings:
$2,415
Cost:
$895
$2,336 40,256 - - $79 - - - - - $2,336
40,256
kWh
-
-
kW-months/year
$79
-
$
-
-
$
-
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$899
Cost:
$30
$869 14,976 - - $30 - - - - - $869
14,976
kWh
-
-
kW-months/year
$30
-
$
-
-
$
-
-
$
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$778
Cost:
$990
$752 12,961 - - $26 - - - - - $752
12,961
kWh
-
-
kW-months/year
$26
-
$
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$755
Cost:
$525
$290 4,993 - - $10 - $455 - - - $290
4,993
kWh
-
-
kW-months/year
$10
-
$
$455
-
$
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$754
Cost:
$1,120
$729 12,571 - - $25 - - - - - $729
12,571
kWh
-
-
kW-months/year
$25
-
$
-
-
$
-
-
$
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$261
Cost:
$30
$252 4,342 - - $9 - - - - - $252
4,342
kWh
-
-
kW-months/year
$9
-
$
-
-
$
-
-
$
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$170
Cost:
$270
$164 2,830 - - $6 - - - - - $164
2,830
kWh
-
-
kW-months/year
$6
-
$
-
-
$
-
-
$
09: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$5,500
Cost:
$1,050
- - - - - - $3,000 - $2,500 - -
-
kWh
-
-
kW-months/year
-
-
$
$3,000
-
$
$2,500
-
$
TOTAL RECOMMENDED Savings:
$16,461
Cost:
$5,735
$9,197 158,507 $972 168 $337 - $3,455 - $2,500 - $9,197
158,507
kWh
$972
168
kW-months/year
$337
-
$
$3,455
-
$
$2,500
-
$
TOTAL IMPLEMENTED Savings:
$9,428
Cost:
$3,170
$8,155 140,553 $972 168 $301 - - - - - $8,155
140,553
kWh
$972
168
kW-months/year
$301
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees Personnel Changes One-time Revenue or Avoided Cost