Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2005 |
Principal Product | Ship Repair |
NAICS | 336611 - Ship Building and Repairing |
SIC | 3731 - Ship Building And Repairing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 150 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $239,894 | 3,465,000 | kWh | $0.07 |
Electricity Demand | $1,455 | 2,646 | kW-months/year | $0.55 |
Electricity Fees | $9,298 | - | $ | - |
Other Gas | $12,886 | 1,018 | MMBtu | $12.66 |
TOTAL ENERGY COSTS | $263,533 | |||
RECOMMENDED SAVINGS* | $31,331 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,791 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Other Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,791 Cost: $3,680 |
$10,386 | 150,020 | - | - | $405 | - | - | - | - | - | - | - |
$10,386 150,020 kWh |
- - kW-months/year |
$405 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $6,317 Cost: $381 |
- | - | - | - | - | - | $6,317 | 499 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,317 499 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $5,700 Cost: $1,530 |
$5,486 | 79,248 | - | - | $214 | - | - | - | - | - | - | - |
$5,486 79,248 kWh |
- - kW-months/year |
$214 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $1,452 Cost: $845 |
$1,397 | 20,184 | - | - | $55 | - | - | - | - | - | - | - |
$1,397 20,184 kWh |
- - kW-months/year |
$55 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $764 Cost: $240 |
$728 | 10,513 | $7 | 13 | $29 | - | - | - | - | - | - | - |
$728 10,513 kWh |
$7 13 kW-months/year |
$29 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $753 Cost: $240 |
$725 | 10,469 | - | - | $28 | - | - | - | - | - | - | - |
$725 10,469 kWh |
- - kW-months/year |
$28 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $814 Cost: $525 |
$346 | 4,993 | - | - | $13 | - | - | - | $455 | - | - | - |
$346 4,993 kWh |
- - kW-months/year |
$13 - $ |
- - MMBtu |
$455 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $4,740 Cost: $490 |
- | - | - | - | - | - | - | - | $2,240 | - | $2,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,240 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,331 Cost: $7,931 |
$19,068 | 275,427 | $7 | 13 | $744 | - | $6,317 | 499 | $2,695 | - | $2,500 | - | $19,068 275,427 kWh |
$7 13 kW-months/year |
$744 - $ |
$6,317 499 MMBtu |
$2,695 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,791 Cost: $3,680 |
$10,386 | 150,020 | - | - | $405 | - | - | - | - | - | - | - | $10,386 150,020 kWh |
- - kW-months/year |
$405 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Other Gas | Personnel Changes | One-time Revenue or Avoided Cost |