Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2005 |
Principal Product | Rice Milling |
NAICS | 311211 - Flour Milling |
SIC | 2044 - Rice Milling |
Sales | $10,000,000-$50,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 112,000 |
Annual Production | 2,250,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $40,852 | 760,474 | kWh | $0.05 |
Electricity Demand | $29,815 | 4,253 | kW-months/year | $7.01 |
Electricity Fees | $2,684 | - | $ | - |
Natural Gas | $50,775 | 5,252 | MMBtu | $9.67 |
TOTAL ENERGY COSTS | $124,126 | |||
RECOMMENDED SAVINGS* | $181,636 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $177,100 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,146 Cost: $2,000 |
$12,436 | 231,490 | $3,119 | 445 | $591 | - | - | - | - | - | - | - |
$12,436 231,490 kWh |
$3,119 445 kW-months/year |
$591 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,111 Cost: $50 |
$2,997 | 55,789 | - | - | $114 | - | - | - | - | - | - | - |
$2,997 55,789 kWh |
- - kW-months/year |
$114 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,676 Cost: $400 |
$2,580 | 48,022 | - | - | $96 | - | - | - | - | - | - | - |
$2,580 48,022 kWh |
- - kW-months/year |
$96 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,991 Cost: - |
- | - | - | - | - | - | $1,991 | 206 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,991 206 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,445 Cost: - |
$1,392 | 25,907 | - | - | $53 | - | - | - | - | - | - | - |
$1,392 25,907 kWh |
- - kW-months/year |
$53 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,100 Cost: - |
$1,060 | 19,727 | - | - | $40 | - | - | - | - | - | - | - |
$1,060 19,727 kWh |
- - kW-months/year |
$40 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $667 Cost: $150 |
- | - | - | - | - | - | $667 | 69 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$667 69 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $154,500 Cost: $2,500 |
- | - | - | - | - | - | - | - | $152,000 | - | $2,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$152,000 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $181,636 Cost: $5,100 |
$20,465 | 380,935 | $3,119 | 445 | $894 | - | $2,658 | 275 | $152,000 | - | $2,500 | - | $20,465 380,935 kWh |
$3,119 445 kW-months/year |
$894 - $ |
$2,658 275 MMBtu |
$152,000 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $177,100 Cost: $5,100 |
$18,013 | 335,301 | $3,119 | 445 | $801 | - | $667 | 69 | $152,000 | - | $2,500 | - | $18,013 335,301 kWh |
$3,119 445 kW-months/year |
$801 - $ |
$667 69 MMBtu |
$152,000 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |