Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2005 |
Principal Product | Newspaper |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2711 - Newspapers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 2,484 Tons |
Production Hrs. Annual | 2,912 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $101,948 | 1,309,680 | kWh | $0.08 |
Electricity Demand | $31,028 | 5,642 | kW-months/year | $5.50 |
Electricity Fees | $5,402 | - | $ | - |
Natural Gas | $1,091 | 91 | MMBtu | $11.99 |
TOTAL ENERGY COSTS | $139,469 | |||
RECOMMENDED SAVINGS* | $153,799 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,833 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $25,544 Cost: - |
$101,945 | 1,309,680 | $31,031 | 5,642 | $(-4,192) | - | $(-103,240) | (-11,561) | - | - | - | - |
$101,945 1,309,680 kWh |
$31,031 5,642 kW-months/year |
$(-4,192) - $ |
$(-103,240) (-11,561) MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $10,617 Cost: $500 |
$10,228 | 131,393 | - | - | $389 | - | - | - | - | - | - | - |
$10,228 131,393 kWh |
- - kW-months/year |
$389 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,216 Cost: $750 |
$4,046 | 51,978 | $979 | 178 | $191 | - | - | - | - | - | - | - |
$4,046 51,978 kWh |
$979 178 kW-months/year |
$191 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,367 Cost: - |
$3,244 | 41,671 | - | - | $123 | - | - | - | - | - | - | - |
$3,244 41,671 kWh |
- - kW-months/year |
$123 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $165 Cost: - |
$159 | 2,043 | - | - | $6 | - | - | - | - | - | - | - |
$159 2,043 kWh |
- - kW-months/year |
$6 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $108,500 Cost: - |
- | - | - | - | - | - | - | - | $106,000 | - | $2,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$106,000 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $390 Cost: - |
- | - | - | - | - | - | - | - | $390 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$390 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $153,799 Cost: $1,250 |
$119,622 | 1,536,765 | $32,010 | 5,820 | $(-3,483) | - | $(-103,240) | (-11,561) | $106,390 | - | $2,500 | - | $119,622 1,536,765 kWh |
$32,010 5,820 kW-months/year |
$(-3,483) - $ |
$(-103,240) (-11,561) MMBtu |
$106,390 - $ |
$2,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,833 Cost: $1,250 |
$14,274 | 183,371 | $979 | 178 | $580 | - | - | - | - | - | - | - | $14,274 183,371 kWh |
$979 178 kW-months/year |
$580 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |