Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2006 |
Principal Product | Fabricated parts |
NAICS | 332313 - Plate Work Manufacturing |
SIC | 3443 - Fabricated Plate Work (boiler Shops) |
Sales | $50,000,000-$100,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 27,250 |
Annual Production | 500,000 Pieces |
Production Hrs. Annual | 5,928 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,958 | 1,243,750 | kWh | $0.06 |
Electricity Demand | $35,123 | 4,652 | kW-months/year | $7.55 |
Electricity Fees | $4,083 | - | $ | - |
TOTAL ENERGY COSTS | $113,164 | |||
RECOMMENDED SAVINGS* | $20,617 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,628 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $8,455 Cost: $575 |
$6,133 | 103,147 | - | - | $227 | - | $595 | - | $1,500 | - |
$6,133 103,147 kWh |
- - kW-months/year |
$227 - $ |
$595 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $8,399 Cost: $1,521 |
$8,099 | 136,211 | - | - | $300 | - | - | - | - | - |
$8,099 136,211 kWh |
- - kW-months/year |
$300 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,122 Cost: $440 |
$1,082 | 18,196 | - | - | $40 | - | - | - | - | - |
$1,082 18,196 kWh |
- - kW-months/year |
$40 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $932 Cost: $372 |
$635 | 10,677 | $264 | 35 | $33 | - | - | - | - | - |
$635 10,677 kWh |
$264 35 kW-months/year |
$33 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $538 Cost: $270 |
$519 | 8,728 | - | - | $19 | - | - | - | - | - |
$519 8,728 kWh |
- - kW-months/year |
$19 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $527 Cost: $30 |
$508 | 8,542 | - | - | $19 | - | - | - | - | - |
$508 8,542 kWh |
- - kW-months/year |
$19 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $509 Cost: $350 |
$198 | 3,329 | - | - | $7 | - | $304 | - | - | - |
$198 3,329 kWh |
- - kW-months/year |
$7 - $ |
$304 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $135 Cost: $198 |
$130 | 2,189 | - | - | $5 | - | - | - | - | - |
$130 2,189 kWh |
- - kW-months/year |
$5 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,617 Cost: $3,756 |
$17,304 | 291,019 | $264 | 35 | $650 | - | $899 | - | $1,500 | - | $17,304 291,019 kWh |
$264 35 kW-months/year |
$650 - $ |
$899 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,628 Cost: $1,462 |
$2,942 | 49,472 | $264 | 35 | $118 | - | $304 | - | - | - | $2,942 49,472 kWh |
$264 35 kW-months/year |
$118 - $ |
$304 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost |