Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2006 |
Principal Product | Polyethylene |
NAICS | 324199 - All Other Petroleum and Coal Products Manufacturing |
SIC | 2999 - Petroleum And Coal Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 94,700 |
Annual Production | 88,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,353,975 | 25,885,934 | kWh | $0.05 |
Electricity Demand | $296,512 | 44,927 | kW-months/year | $6.60 |
Electricity Fees | $4,903 | - | $ | - |
Natural Gas | $1,814,223 | 269,571 | MMBtu | $6.73 |
TOTAL ENERGY COSTS | $3,469,613 | |||
RECOMMENDED SAVINGS* | $826,634 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $316,725 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Electricity Usage | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $490,346 Cost: $849,320 |
- | - | $429,845 | 63,870 | $60,501 | 50,417,266 |
- - kWh |
$429,845 63,870 MMBtu |
$60,501 50,417,266 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $240,584 Cost: $34,600 |
- | - | $240,584 | 35,748 | - | - |
- - kWh |
$240,584 35,748 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $72,332 Cost: $3,042 |
$72,332 | 1,382,760 | - | - | - | - |
$72,332 1,382,760 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $14,933 Cost: $122,080 |
$14,933 | 285,462 | - | - | - | - |
$14,933 285,462 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,024 Cost: $300 |
$3,024 | 57,817 | - | - | - | - |
$3,024 57,817 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,093 Cost: $313 |
- | - | $2,093 | 311 | - | - |
- - kWh |
$2,093 311 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,716 Cost: $913 |
- | - | $1,716 | 255 | - | - |
- - kWh |
$1,716 255 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,606 Cost: $150 |
$1,606 | 30,704 | - | - | - | - |
$1,606 30,704 kWh |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $826,634 Cost: $1,010,718 |
$91,895 | 1,756,743 | $674,238 | 100,184 | $60,501 | 50,417,266 | $91,895 1,756,743 kWh |
$674,238 100,184 MMBtu |
$60,501 50,417,266 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $316,725 Cost: $38,868 |
$72,332 | 1,382,760 | $244,393 | 36,314 | - | - | $72,332 1,382,760 kWh |
$244,393 36,314 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Electricity Usage | Natural Gas | Water Disposal |