Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2006 |
Principal Product | HF and Genetron |
NAICS | 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 625,000 |
Annual Production | 163,000 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $8,226,184 | 153,691,694 | kWh | $0.05 |
Electricity Demand | $2,465,328 | 240,373 | kW-months/year | $10.26 |
Natural Gas | $17,911,478 | 2,010,024 | MMBtu | $8.91 |
TOTAL ENERGY COSTS | $28,602,990 | |||
RECOMMENDED SAVINGS* | $6,309,584 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,715,248 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1231 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS |
Savings: $3,334,582 Cost: $60,000 |
- | - | - | - | $3,334,582 | 374,418 | - | - |
- - kWh |
- - kW-months/year |
$3,334,582 374,418 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $2,369,946 Cost: $5,024,000 |
$4,688,352 | 87,600,000 | $1,231,200 | 120,000 | $(-3,549,606) | (-413,707) | - | - |
$4,688,352 87,600,000 kWh |
$1,231,200 120,000 kW-months/year |
$(-3,549,606) (-413,707) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $323,360 Cost: $14,100 |
- | - | - | - | $323,360 | 36,308 | - | - |
- - kWh |
- - kW-months/year |
$323,360 36,308 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $185,638 Cost: $4,644 |
- | - | - | - | $185,638 | 20,844 | - | - |
- - kWh |
- - kW-months/year |
$185,638 20,844 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $45,203 Cost: $6,300 |
$45,203 | 844,595 | - | - | - | - | - | - |
$45,203 844,595 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $32,924 Cost: $11,000 |
$32,924 | 615,165 | - | - | - | - | - | - |
$32,924 615,165 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $12,103 Cost: $1,218 |
- | - | - | - | $12,103 | 1,359 | - | - |
- - kWh |
- - kW-months/year |
$12,103 1,359 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,818 Cost: $3,500 |
$1,782 | 33,288 | - | - | - | - | $3,036 | - |
$1,782 33,288 kWh |
- - kW-months/year |
- - MMBtu |
$3,036 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,010 Cost: $2,813 |
$1,010 | 18,865 | - | - | - | - | - | - |
$1,010 18,865 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $6,309,584 Cost: $5,127,575 |
$4,769,271 | 89,111,913 | $1,231,200 | 120,000 | $306,077 | 19,222 | $3,036 | - | $4,769,271 89,111,913 kWh |
$1,231,200 120,000 kW-months/year |
$306,077 19,222 MMBtu |
$3,036 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,715,248 Cost: $81,618 |
$45,203 | 844,595 | - | - | $3,670,045 | 412,085 | - | - | $45,203 844,595 kWh |
- - kW-months/year |
$3,670,045 412,085 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |