Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2006 |
Principal Product | Rice |
NAICS | 311212 - Rice Milling |
SIC | 2044 - Rice Milling |
Sales | $1,000,000-$5,000,000 |
# of Employees | 14 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 52,650,000 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $60,771 | 560,671 | kWh | $0.11 |
Electricity Demand | $14,067 | 781 | kW-months/year | $18.01 |
Electricity Fees | $2,946 | - | $ | - |
Natural Gas | $139,239 | 10,456 | MMBtu | $13.32 |
TOTAL ENERGY COSTS | $217,023 | |||
RECOMMENDED SAVINGS* | $37,377 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,622 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $21,816 Cost: $14,656 |
$20,997 | 193,697 | - | - | $819 | - | - | - | - | - | - | - |
$20,997 193,697 kWh |
- - kW-months/year |
$819 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,463 Cost: $1,022 |
$8,197 | 75,617 | $1,873 | 104 | $393 | - | - | - | - | - | - | - |
$8,197 75,617 kWh |
$1,873 104 kW-months/year |
$393 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,218 Cost: $80 |
$14 | 125 | - | - | $1 | - | - | - | $203 | - | $1,000 | - |
$14 125 kWh |
- - kW-months/year |
$1 - $ |
- - MMBtu |
$203 - $ |
$1,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,082 Cost: $20 |
$663 | 6,117 | $378 | 21 | $41 | - | - | - | - | - | - | - |
$663 6,117 kWh |
$378 21 kW-months/year |
$41 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $959 Cost: $151 |
- | - | - | - | - | - | $959 | 72 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$959 72 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $900 Cost: $300 |
- | - | - | - | - | - | - | - | $900 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$900 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $619 Cost: $150 |
$596 | 5,501 | - | - | $23 | - | - | - | - | - | - | - |
$596 5,501 kWh |
- - kW-months/year |
$23 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $320 Cost: $50 |
- | - | - | - | - | - | $320 | 24 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$320 24 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $37,377 Cost: $16,429 |
$30,467 | 281,057 | $2,251 | 125 | $1,277 | - | $1,279 | 96 | $1,103 | - | $1,000 | - | $30,467 281,057 kWh |
$2,251 125 kW-months/year |
$1,277 - $ |
$1,279 96 MMBtu |
$1,103 - $ |
$1,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,622 Cost: $1,573 |
$8,874 | 81,859 | $2,251 | 125 | $435 | - | $959 | 72 | $1,103 | - | $1,000 | - | $8,874 81,859 kWh |
$2,251 125 kW-months/year |
$435 - $ |
$959 72 MMBtu |
$1,103 - $ |
$1,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||