Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2007 |
Principal Product | Rope |
NAICS | 314994 - Rope, Cordage, Twine, Tire Cord, and Tire Fabric Mills |
SIC | 2298 - Cordage And Twine |
Sales | $5,000,000-$10,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 78,000 |
Annual Production | 5,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $304,951 | 3,657,365 | kWh | $0.08 |
Natural Gas | $94,323 | 9,432 | MMBtu | $10.00 |
TOTAL ENERGY COSTS | $399,274 | |||
RECOMMENDED SAVINGS* | $73,044 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,442 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $29,656 Cost: $10,860 |
$30,232 | 362,583 | - | - | - | - | $(-576) | - | - | - | - | - |
$30,232 362,583 kWh |
- - MMBtu |
- - $ |
$(-576) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $14,779 Cost: $1,384 |
$14,779 | 177,249 | - | - | - | - | - | - | - | - | - | - |
$14,779 177,249 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $9,981 Cost: $150 |
$8,481 | 101,712 | - | - | - | - | - | - | - | - | $1,500 | - |
$8,481 101,712 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$1,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,854 Cost: $2,400 |
$8,854 | 106,186 | - | - | - | - | - | - | - | - | - | - |
$8,854 106,186 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $2,388 Cost: $542 |
$2,388 | 28,645 | - | - | - | - | - | - | - | - | - | - |
$2,388 28,645 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,920 Cost: $1,147 |
- | - | - | - | - | - | - | - | $1,920 | - | - | - |
- - kWh |
- - MMBtu |
- - $ |
- - $ |
$1,920 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,744 Cost: $1,050 |
$833 | 9,986 | - | - | $911 | - | - | - | - | - | - | - |
$833 9,986 kWh |
- - MMBtu |
$911 - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,696 Cost: $912 |
$1,696 | 20,340 | - | - | - | - | - | - | - | - | - | - |
$1,696 20,340 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,240 Cost: $428 |
- | - | $1,240 | 124 | - | - | - | - | - | - | - | - |
- - kWh |
$1,240 124 MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $583 Cost: $668 |
$583 | 6,989 | - | - | - | - | - | - | - | - | - | - |
$583 6,989 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $203 Cost: $120 |
$203 | 2,440 | - | - | - | - | - | - | - | - | - | - |
$203 2,440 kWh |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,044 Cost: $19,661 |
$68,049 | 816,130 | $1,240 | 124 | $911 | - | $(-576) | - | $1,920 | - | $1,500 | - | $68,049 816,130 kWh |
$1,240 124 MMBtu |
$911 - $ |
$(-576) - $ |
$1,920 - $ |
$1,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,442 Cost: $17,181 |
$52,687 | 631,892 | - | - | $911 | - | $(-576) | - | $1,920 | - | $1,500 | - | $52,687 631,892 kWh |
- - MMBtu |
$911 - $ |
$(-576) - $ |
$1,920 - $ |
$1,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||