Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2008
Principal Product Cosmetics
NAICS 325620 - Toilet Preparation Manufacturing
SIC 2844 - Toilet Preparations
Sales $100,000,000-$500,000,000
# of Employees 650
Plant Area (Sq.Ft.) 446,000
Annual Production 254,000,000 Pieces
Production Hrs. Annual 8,736
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,743,275 20,748,902 kWh $0.08
Natural Gas $378,888 39,339 MMBtu $9.63
TOTAL ENERGY COSTS $2,122,163
RECOMMENDED SAVINGS* $695,822 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $131,090
#|Description Savings
Cost
Status Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes
$ kWh $ MMBtu $ $
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$463,124
Cost:
$9,955
$463,124 5,512,068 - - - - $463,124
5,512,068
kWh
-
-
MMBtu
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$116,005
Cost:
$24,680
$116,005 1,380,686 - - - - $116,005
1,380,686
kWh
-
-
MMBtu
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$93,199
Cost:
$40,662
$93,199 1,109,244 - - - - $93,199
1,109,244
kWh
-
-
MMBtu
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$12,169
Cost:
$2,120
$12,169 144,829 - - - - $12,169
144,829
kWh
-
-
MMBtu
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,739
Cost:
$3,400
$1,482 17,636 $3,257 340 - - $1,482
17,636
kWh
$3,257
340
MMBtu
-
-
$
06: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$3,670
Cost:
$3,894
$3,670 43,680 - - - - $3,670
43,680
kWh
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,916
Cost:
$1,750
$1,398 16,644 - - $1,518 - $1,398
16,644
kWh
-
-
MMBtu
$1,518
-
$
TOTAL RECOMMENDED Savings:
$695,822
Cost:
$86,461
$691,047 8,224,787 $3,257 340 $1,518 - $691,047
8,224,787
kWh
$3,257
340
MMBtu
$1,518
-
$
TOTAL IMPLEMENTED Savings:
$131,090
Cost:
$28,550
$129,572 1,542,159 - - $1,518 - $129,572
1,542,159
kWh
-
-
MMBtu
$1,518
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes