Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2009 |
Principal Product | Canned Sweet Potatoes |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2035 - Pickles, Sauces, And Salad Dressings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 202 |
Plant Area (Sq.Ft.) | 12,500 |
Annual Production | 160,000,000 Pounds |
Production Hrs. Annual | 4,500 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $286,847 | 3,706,592 | kWh | $0.08 |
Electricity Demand | $52,316 | 12,698 | kW-months/year | $4.12 |
Electricity Fees | $7,963 | - | $ | - |
Natural Gas | $760,085 | 92,540 | MMBtu | $8.21 |
TOTAL ENERGY COSTS | $1,107,211 | |||
RECOMMENDED SAVINGS* | $12,449 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,866 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,918 Cost: $4,600 |
$6,759 | 87,334 | - | - | $159 | - | - | - |
$6,759 87,334 kWh |
- - kW-months/year |
$159 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,488 Cost: $30 |
$1,454 | 18,789 | - | - | $34 | - | - | - |
$1,454 18,789 kWh |
- - kW-months/year |
$34 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,523 Cost: $910 |
$668 | 8,634 | $49 | 12 | $17 | - | $789 | - |
$668 8,634 kWh |
$49 12 kW-months/year |
$17 - $ |
$789 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $967 Cost: $120 |
$945 | 12,217 | - | - | $22 | - | - | - |
$945 12,217 kWh |
- - kW-months/year |
$22 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $676 Cost: $1,155 |
$660 | 8,531 | - | - | $16 | - | - | - |
$660 8,531 kWh |
- - kW-months/year |
$16 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $460 Cost: $120 |
$449 | 5,796 | - | - | $11 | - | - | - |
$449 5,796 kWh |
- - kW-months/year |
$11 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $417 Cost: $467 |
$407 | 5,256 | - | - | $10 | - | - | - |
$407 5,256 kWh |
- - kW-months/year |
$10 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $12,449 Cost: $7,402 |
$11,342 | 146,557 | $49 | 12 | $269 | - | $789 | - | $11,342 146,557 kWh |
$49 12 kW-months/year |
$269 - $ |
$789 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,866 Cost: $4,750 |
$8,662 | 111,919 | - | - | $204 | - | - | - | $8,662 111,919 kWh |
- - kW-months/year |
$204 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |