Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2010
Principal Product Environmental Waste Disposal
NAICS 562211 - Hazardous Waste Treatment and Disposal
SIC 4953 - Refuse Systems
Sales $10,000,000-$50,000,000
# of Employees 260
Plant Area (Sq.Ft.) 200,000
Annual Production 10,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,286,142 39,239,592 kWh $0.06
Natural Gas $2,553,072 287,456 MMBtu $8.88
TOTAL ENERGY COSTS $4,839,214
RECOMMENDED SAVINGS* $280,848 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $279,493
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$138,978
Cost:
$13,140
- - $138,978 15,615 -
-
kWh
$138,978
15,615
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$132,650
Cost:
$40,600
$132,650 2,276,862 - - $132,650
2,276,862
kWh
-
-
MMBtu
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$7,865
Cost:
$750
$7,865 135,000 - - $7,865
135,000
kWh
-
-
MMBtu
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$612
Cost:
$934
$612 10,512 - - $612
10,512
kWh
-
-
MMBtu
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$389
Cost:
$335
$389 6,680 - - $389
6,680
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$254
Cost:
$1,855
$254 4,368 - - $254
4,368
kWh
-
-
MMBtu
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$100
Cost:
$120
$100 1,721 - - $100
1,721
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$280,848
Cost:
$57,734
$141,870 2,435,143 $138,978 15,615 $141,870
2,435,143
kWh
$138,978
15,615
MMBtu
TOTAL IMPLEMENTED Savings:
$279,493
Cost:
$54,490
$140,515 2,411,862 $138,978 15,615 $140,515
2,411,862
kWh
$138,978
15,615
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas