Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2011
Principal Product valves
NAICS 332911 - Industrial Valve Manufacturing
SIC 3491 - Industrial Valves
Sales $100,000,000-$500,000,000
# of Employees 500
Plant Area (Sq.Ft.) 358,000
Annual Production 15,000 Pieces
Production Hrs. Annual 4,160
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,025,232 19,152,000 kWh $0.05
Natural Gas $49,152 4,227 MMBtu $11.63
TOTAL ENERGY COSTS $1,074,384
RECOMMENDED SAVINGS* $126,962 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $126,027
#|Description Savings
Cost
Status Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes
$ kWh $ MMBtu $ $
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$102,711
Cost:
$10,348
- - - - $102,711 - -
-
kWh
-
-
MMBtu
$102,711
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$17,376
Cost:
$12,200
$17,376 324,606 - - - - $17,376
324,606
kWh
-
-
MMBtu
-
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$4,789
Cost:
$5,670
$4,789 89,463 - - - - $4,789
89,463
kWh
-
-
MMBtu
-
-
$
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$935
Cost:
$1,838
$935 17,472 - - - - $935
17,472
kWh
-
-
MMBtu
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$605
Cost:
$4,020
$605 11,311 - - - - $605
11,311
kWh
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$366
Cost:
$3,220
$366 6,839 - - - - $366
6,839
kWh
-
-
MMBtu
-
-
$
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$145
Cost:
$356
- - $145 13 - - -
-
kWh
$145
13
MMBtu
-
-
$
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$35
Cost:
$56
$35 645 - - - - $35
645
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$126,962
Cost:
$37,708
$24,106 450,336 $145 13 $102,711 - $24,106
450,336
kWh
$145
13
MMBtu
$102,711
-
$
TOTAL IMPLEMENTED Savings:
$126,027
Cost:
$35,870
$23,171 432,864 $145 13 $102,711 - $23,171
432,864
kWh
$145
13
MMBtu
$102,711
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes