Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2011 |
Principal Product | Chemicals |
NAICS | 333314 - Optical Instrument and Lens Manufacturing |
SIC | 3827 - Optical Instruments And Lenses |
Sales | $10,000,000-$50,000,000 |
# of Employees | 83 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 130,000 Pieces |
Production Hrs. Annual | 8,136 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $650,431 | 10,963,750 | kWh | $0.06 |
Electricity Demand | $86,054 | 20,887 | kW-months/year | $4.12 |
Electricity Fees | $35,258 | - | $ | - |
TOTAL ENERGY COSTS | $771,743 | |||
RECOMMENDED SAVINGS* | $145,772 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $140,351 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $121,680 Cost: $22,440 |
- | - | - | - | - | - | $121,680 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$121,680 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $7,278 Cost: $4,106 |
- | - | - | - | - | - | $7,278 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$7,278 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,642 Cost: $1,680 |
$6,338 | 106,829 | - | - | $304 | - | - | - | - | - |
$6,338 106,829 kWh |
- - kW-months/year |
$304 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,751 Cost: $11,200 |
$4,160 | 70,117 | $374 | 91 | $217 | - | - | - | - | - |
$4,160 70,117 kWh |
$374 91 kW-months/year |
$217 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $2,231 Cost: $270 |
$698 | 11,765 | - | - | $33 | - | - | - | $1,500 | - |
$698 11,765 kWh |
- - kW-months/year |
$33 - $ |
- - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,199 Cost: $2,220 |
$2,098 | 35,367 | - | - | $101 | - | - | - | - | - |
$2,098 35,367 kWh |
- - kW-months/year |
$101 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $746 Cost: $1,155 |
$650 | 10,955 | $62 | 15 | $34 | - | - | - | - | - |
$650 10,955 kWh |
$62 15 kW-months/year |
$34 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $238 Cost: $368 |
$207 | 3,494 | $20 | 5 | $11 | - | - | - | - | - |
$207 3,494 kWh |
$20 5 kW-months/year |
$11 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7 Cost: $18 |
$6 | 108 | $1 | 0 | $0 | - | - | - | - | - |
$6 108 kWh |
$1 0 kW-months/year |
$0 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $145,772 Cost: $43,457 |
$14,157 | 238,635 | $457 | 111 | $700 | - | $128,958 | - | $1,500 | - | $14,157 238,635 kWh |
$457 111 kW-months/year |
$700 - $ |
$128,958 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $140,351 Cost: $39,426 |
$10,498 | 176,946 | $374 | 91 | $521 | - | $128,958 | - | - | - | $10,498 176,946 kWh |
$374 91 kW-months/year |
$521 - $ |
$128,958 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost |