IAC logo
IAC Assessment: LL0362
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0362
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2011
Principal Product Poly Bags
NAICS 326111 - Plastics Bag and Pouch Manufacturing
SIC 2673 - Bags: Plastics, Laminated, & Coated
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 146,000
Annual Production 12,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $197,015 3,068,000 kWh $0.06
Electricity Demand $69,440 6,944 kW-months/year $10.00
Electricity Fees $5,329 - $ -
Natural Gas $1,135 108 MMBtu $10.51
TOTAL ENERGY COSTS $275,221
RECOMMENDED SAVINGS* $27,210 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $24,333
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$18,083
Cost:
$810
$17,728 276,058 - - $355 - - - $17,728
276,058
kWh
-
-
kW-months/year
$355
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,629
Cost:
$61,377
$4,326 67,356 $217 22 $87 - - - $4,326
67,356
kWh
$217
22
kW-months/year
$87
-
$
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,621
Cost:
$360
$1,269 19,757 $320 32 $32 - - - $1,269
19,757
kWh
$320
32
kW-months/year
$32
-
$
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,287
Cost:
$395
$887 13,810 $375 38 $25 - - - $887
13,810
kWh
$375
38
kW-months/year
$25
-
$
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$432
Cost:
$900
$423 6,590 - - $8 - - - $423
6,590
kWh
-
-
kW-months/year
$8
-
$
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$396
Cost:
$280
$149 2,324 $32 3 $4 - $211 - $149
2,324
kWh
$32
3
kW-months/year
$4
-
$
$211
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$308
Cost:
$1,155
$182 2,831 $120 12 $6 - - - $182
2,831
kWh
$120
12
kW-months/year
$6
-
$
-
-
$
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$278
Cost:
$368
$224 3,494 $48 5 $5 - - - $224
3,494
kWh
$48
5
kW-months/year
$5
-
$
-
-
$
09: 2.7134 USE PHOTOCELL CONTROLS Savings:
$177
Cost:
$30
$173 2,700 - - $3 - - - $173
2,700
kWh
-
-
kW-months/year
$3
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$27,210
Cost:
$65,675
$25,362 394,920 $1,113 112 $525 - $211 - $25,362
394,920
kWh
$1,113
112
kW-months/year
$525
-
$
$211
-
$
TOTAL IMPLEMENTED Savings:
$24,333
Cost:
$62,547
$23,323 363,171 $537 54 $473 - - - $23,323
363,171
kWh
$537
54
kW-months/year
$473
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes