Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2001 |
Principal Product | magnets |
NAICS | n/a |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 15,000 Pieces |
Production Hrs. Annual | 2,808 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $76,129 | 613,400 | kWh | $0.12 |
Electricity Demand | $13,332 | 2,472 | kW-months/year | $5.39 |
Electricity Fees | $16,159 | - | $ | - |
Natural Gas | $5,385 | 731 | MMBtu | $7.37 |
TOTAL ENERGY COSTS | $120,455 | |||
RECOMMENDED SAVINGS* | $243,094 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $130,261 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,192 Cost: $3,285 |
$3,882 | 47,673 | $1,310 | 131 | - | - | - | - | - | - |
$3,882 47,673 kWh |
$1,310 131 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN |
Savings: $1,259 Cost: $3,158 |
$821 | 9,950 | $438 | 45 | - | - | - | - | - | - |
$821 9,950 kWh |
$438 45 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,253 Cost: $250 |
$830 | 10,056 | $423 | 43 | - | - | - | - | - | - |
$830 10,056 kWh |
$423 43 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $508 Cost: - |
$253 | 3,068 | $255 | 26 | - | - | - | - | - | - |
$253 3,068 kWh |
$255 26 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $6,282 Cost: $12,475 |
- | - | - | - | $6,282 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,282 - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7197 USE ULTRASONIC CLEANING |
Savings: $100,100 Cost: $90,000 |
- | - | - | - | - | - | $100,100 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$100,100 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $128,500 Cost: - |
- | - | - | - | - | - | $(-87,500) | - | $216,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$(-87,500) - $ |
$216,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $243,094 Cost: $109,168 |
$5,786 | 70,747 | $2,426 | 245 | $6,282 | - | $12,600 | - | $216,000 | - | $5,786 70,747 kWh |
$2,426 245 kW-months/year |
$6,282 - lb |
$12,600 - $ |
$216,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $130,261 Cost: $250 |
$1,083 | 13,124 | $678 | 69 | - | - | $(-87,500) | - | $216,000 | - | $1,083 13,124 kWh |
$678 69 kW-months/year |
- - lb |
$(-87,500) - $ |
$216,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production |