Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2001 |
Principal Product | axles |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $5,000,000-$10,000,000 |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 16,500 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $114,074 | 1,294,080 | kWh | $0.09 |
Electricity Demand | $37,062 | 4,688 | kW-months/year | $7.91 |
Electricity Fees | $2,430 | - | $ | - |
Natural Gas | $112,417 | 17,848 | MMBtu | $6.30 |
TOTAL ENERGY COSTS | $265,983 | |||
RECOMMENDED SAVINGS* | $102,902 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $75,052 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $17,501 Cost: $630 |
$16,141 | 123,210 | $2,140 | 316 | - | - | $(-780) | - | - | - |
$16,141 123,210 kWh |
$2,140 316 kW-months/year |
- - MMBtu |
$(-780) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY |
Savings: $2,859 Cost: $500 |
- | - | - | - | $2,859 | 445 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,859 445 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $1,567 Cost: $3,000 |
$529 | 7,621 | $1,038 | 88 | - | - | - | - | - | - |
$529 7,621 kWh |
$1,038 88 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,741 Cost: $12,000 |
- | - | $4,741 | 397 | - | - | - | - | - | - |
- - kWh |
$4,741 397 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $26,071 Cost: $150 |
- | - | - | - | - | - | - | - | $26,071 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$26,071 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $20,250 Cost: $416 |
$18,016 | 163,950 | $2,234 | 358 | - | - | - | - | - | - |
$18,016 163,950 kWh |
$2,234 358 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $29,913 Cost: $29,612 |
- | - | - | - | - | - | $29,913 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$29,913 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $102,902 Cost: $46,308 |
$34,686 | 294,781 | $10,153 | 1,159 | $2,859 | 445 | $29,133 | - | $26,071 | - | $34,686 294,781 kWh |
$10,153 1,159 kW-months/year |
$2,859 445 MMBtu |
$29,133 - $ |
$26,071 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $75,052 Cost: $33,392 |
$16,670 | 130,831 | $3,178 | 404 | - | - | $29,133 | - | $26,071 | - | $16,670 130,831 kWh |
$3,178 404 kW-months/year |
- - MMBtu |
$29,133 - $ |
$26,071 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |