Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2002 |
Principal Product | one quart plastic oil bottles |
NAICS | n/a |
SIC | 3085 - Plastics Bottles |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 127,000 |
Annual Production | 136,000,000 Pieces |
Production Hrs. Annual | 5,928 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $832,464 | 9,073,943 | kWh | $0.09 |
Electricity Demand | $274,933 | 20,496 | kW-months/year | $13.41 |
Electricity Fees | $43,827 | - | $ | - |
Natural Gas | $24,093 | 3,714 | MMBtu | $6.49 |
TOTAL ENERGY COSTS | $1,175,317 | |||
RECOMMENDED SAVINGS* | $115,923 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $107,048 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,509 Cost: - |
$3,488 | 37,766 | $1,021 | 77 | - | - | - | - | - | - |
$3,488 37,766 kWh |
$1,021 77 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7145 INSTALL SKYLIGHTS |
Savings: $5,597 Cost: $10,400 |
$4,978 | 41,612 | $619 | 78 | - | - | - | - | - | - |
$4,978 41,612 kWh |
$619 78 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,278 Cost: $576 |
$2,505 | 27,117 | $773 | 55 | - | - | - | - | - | - |
$2,505 27,117 kWh |
$773 55 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $306 Cost: $160 |
$133 | 1,431 | $173 | 2 | - | - | - | - | - | - |
$133 1,431 kWh |
$173 2 kW-months/year |
- - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $1,275 Cost: $2,572 |
- | - | - | - | $1,275 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,275 - lb |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $78,909 Cost: $130,043 |
- | - | - | - | - | - | - | - | $78,909 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$78,909 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $22,049 Cost: $60,000 |
- | - | - | - | - | - | $22,049 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$22,049 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $115,923 Cost: $203,751 |
$11,104 | 107,926 | $2,586 | 212 | $1,275 | - | $22,049 | - | $78,909 | - | $11,104 107,926 kWh |
$2,586 212 kW-months/year |
$1,275 - lb |
$22,049 - $ |
$78,909 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $107,048 Cost: $192,775 |
$3,621 | 39,197 | $1,194 | 79 | $1,275 | - | $22,049 | - | $78,909 | - | $3,621 39,197 kWh |
$1,194 79 kW-months/year |
$1,275 - lb |
$22,049 - $ |
$78,909 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Increase in Production |