Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2002 |
Principal Product | frozen pies |
NAICS | n/a |
SIC | 2053 - Frozen Bakery Products, Except Bread |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 76,000 |
Annual Production | 1,200,000 Pieces |
Production Hrs. Annual | 5,280 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $360,621 | 3,395,880 | kWh | $0.11 |
Electricity Demand | $54,165 | 6,504 | kW-months/year | $8.33 |
Electricity Fees | $35,873 | - | $ | - |
Natural Gas | $67,500 | 10,387 | MMBtu | $6.50 |
TOTAL ENERGY COSTS | $518,159 | |||
RECOMMENDED SAVINGS* | $923,279 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7145 INSTALL SKYLIGHTS |
Savings: $6,143 Cost: $10,400 |
$5,775 | 40,357 | $368 | 97 | - | - | - | - | - | - |
$5,775 40,357 kWh |
$368 97 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,578 Cost: - |
$1,441 | 10,070 | $137 | 38 | - | - | - | - | - | - |
$1,441 10,070 kWh |
$137 38 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,854 Cost: $370 |
$2,700 | 18,866 | $154 | 43 | - | - | - | - | - | - |
$2,700 18,866 kWh |
$154 43 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $23,073 Cost: $31,000 |
$16,297 | 113,900 | $6,776 | 1,898 | - | - | - | - | - | - |
$16,297 113,900 kWh |
$6,776 1,898 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $64,833 Cost: $96,800 |
$62,690 | 438,100 | $2,143 | 600 | - | - | - | - | - | - |
$62,690 438,100 kWh |
$2,143 600 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.422 UTILIZE OUTSIDE CONTRACTING |
Savings: $22,623 Cost: $12,000 |
$149,919 | 1,047,725 | $5,124 | 4,112 | $190,080 | - | $(-322,500) | - | - | - |
$149,919 1,047,725 kWh |
$5,124 4,112 kW-months/year |
$190,080 - $ |
$(-322,500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $243,003 Cost: $208,000 |
- | - | - | - | $63,360 | - | $155,643 | - | $24,000 | - |
- - kWh |
- - kW-months/year |
$63,360 - $ |
$155,643 - $ |
$24,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $237,812 Cost: $70,000 |
- | - | - | - | $237,812 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$237,812 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $90,240 Cost: $34,800 |
- | - | - | - | - | - | - | - | $90,240 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$90,240 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $231,120 Cost: $395,000 |
- | - | - | - | $231,120 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$231,120 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $923,279 Cost: $858,370 |
$238,822 | 1,669,018 | $14,702 | 6,788 | $722,372 | - | $(-166,857) | - | $114,240 | - | $238,822 1,669,018 kWh |
$14,702 6,788 kW-months/year |
$722,372 - $ |
$(-166,857) - $ |
$114,240 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||