Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2005 |
Principal Product | thread rolling |
NAICS | 332721 - Precision Turned Product Manufacturing |
SIC | 3451 - Screw Machine Products |
Sales | $1,000,000-$5,000,000 |
# of Employees | 39 |
Plant Area (Sq.Ft.) | 29,000 |
Annual Production | 261,000 Pieces |
Production Hrs. Annual | 2,250 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $18,265 | 351,360 | kWh | $0.05 |
Electricity Demand | $28,693 | 2,321 | kW-months/year | $12.36 |
Electricity Fees | $6,750 | - | $ | - |
Natural Gas | $3,143 | 305 | MMBtu | $10.30 |
TOTAL ENERGY COSTS | $56,851 | |||
RECOMMENDED SAVINGS* | $79,335 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $429 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $1,633 Cost: - |
$770 | 27,281 | $863 | 62 | - | - | - | - | - | - | - | - |
$770 27,281 kWh |
$863 62 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $429 Cost: $280 |
$202 | 3,436 | $227 | 17 | - | - | - | - | - | - | - | - |
$202 3,436 kWh |
$227 17 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $2,100 Cost: - |
- | - | - | - | - | - | $2,100 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,100 - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $2,898 Cost: $2,000 |
$(-477) | (-8,127) | - | - | - | - | - | - | - | - | $3,375 | - |
$(-477) (-8,127) kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
$3,375 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $45,000 Cost: $32,440 |
- | - | - | - | - | - | - | - | $45,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$45,000 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.624 HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME |
Savings: $24,485 Cost: $2,000 |
$(-4,127) | (-70,272) | $(-6,388) | (-466) | $(-70,000) | - | - | - | - | - | $105,000 | - |
$(-4,127) (-70,272) kWh |
$(-6,388) (-466) kW-months/year |
$(-70,000) - $ |
- - $ |
- - $ |
$105,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7145 INSTALL SKYLIGHTS |
Savings: $2,790 Cost: $7,500 |
$2,179 | 37,089 | $611 | 44 | - | - | - | - | - | - | - | - |
$2,179 37,089 kWh |
$611 44 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,335 Cost: $44,220 |
$(-1,453) | (-10,593) | $(-4,687) | (-343) | $(-70,000) | - | $2,100 | - | $45,000 | - | $108,375 | - | $(-1,453) (-10,593) kWh |
$(-4,687) (-343) kW-months/year |
$(-70,000) - $ |
$2,100 - $ |
$45,000 - $ |
$108,375 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $429 Cost: $280 |
$202 | 3,436 | $227 | 17 | - | - | - | - | - | - | - | - | $202 3,436 kWh |
$227 17 kW-months/year |
- - $ |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Primary Product | Increase in Production |