Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2006 |
Principal Product | Digital labels |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2759 - Commercial Printing, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 2,000,000 Thousand Feet |
Production Hrs. Annual | 3,510 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,949 | 246,813 | kWh | $0.08 |
Electricity Demand | $12,373 | 1,308 | kW-months/year | $9.46 |
Electricity Fees | $3,071 | - | $ | - |
TOTAL ENERGY COSTS | $36,393 | |||
RECOMMENDED SAVINGS* | $446,398 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $442,876 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $3,522 Cost: $2,400 |
$3,522 | 24,288 | - | - | - | - | - | - | - | - |
$3,522 24,288 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,219 Cost: $2,200 |
$1,503 | 17,064 | $716 | 72 | - | - | - | - | - | - |
$1,503 17,064 kWh |
$716 72 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $225,208 Cost: $12,980 |
$131 | 1,542 | $77 | 8 | $225,000 | - | - | - | - | - |
$131 1,542 kWh |
$77 8 kW-months/year |
$225,000 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $178,334 Cost: $5,400 |
$(-1,047) | (-12,341) | $(-619) | (-33) | - | - | - | - | $180,000 | - |
$(-1,047) (-12,341) kWh |
$(-619) (-33) kW-months/year |
- - $ |
- - $ |
$180,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $16,864 Cost: $1,000 |
$(-1,319) | (-14,980) | $(-2,857) | (-288) | - | - | $21,040 | - | - | - |
$(-1,319) (-14,980) kWh |
$(-2,857) (-288) kW-months/year |
- - $ |
$21,040 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $20,251 Cost: $1,000 |
$(-471) | (-5,553) | $(-278) | (-29) | - | - | - | - | $21,000 | - |
$(-471) (-5,553) kWh |
$(-278) (-29) kW-months/year |
- - $ |
- - $ |
$21,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $446,398 Cost: $24,980 |
$2,319 | 10,020 | $(-2,961) | (-270) | $225,000 | - | $21,040 | - | $201,000 | - | $2,319 10,020 kWh |
$(-2,961) (-270) kW-months/year |
$225,000 - $ |
$21,040 - $ |
$201,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $442,876 Cost: $22,580 |
$(-1,203) | (-14,268) | $(-2,961) | (-270) | $225,000 | - | $21,040 | - | $201,000 | - | $(-1,203) (-14,268) kWh |
$(-2,961) (-270) kW-months/year |
$225,000 - $ |
$21,040 - $ |
$201,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production |