Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2006 |
Principal Product | animal feed |
NAICS | 311119 - Other Animal Food Manufacturing |
SIC | 2048 - Prepared Feeds, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 175,100 |
Annual Production | 1,000,000 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $884,272 | 15,051,920 | kWh | $0.06 |
Electricity Demand | $572,583 | 34,659 | kW-months/year | $16.52 |
Natural Gas | $3,764,262 | 380,227 | MMBtu | $9.90 |
TOTAL ENERGY COSTS | $5,221,117 | |||
RECOMMENDED SAVINGS* | $423,730 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $106,053 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,819 Cost: - |
$3,302 | 37,521 | $517 | 52 | - | - | - | - | - | - | - | - |
$3,302 37,521 kWh |
$517 52 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,118 Cost: - |
$1,868 | 27,980 | - | - | - | - | - | - | $2,250 | - | - | - |
$1,868 27,980 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$2,250 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $50,309 Cost: $1,000 |
- | - | - | - | $26,651 | 2,692 | - | - | $11,829 | - | $11,829 | - |
- - kWh |
- - kW-months/year |
$26,651 2,692 MMBtu |
- - $ |
$11,829 - $ |
$11,829 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $20,043 Cost: $1,000 |
- | - | - | - | $20,043 | 332 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$20,043 332 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $297,634 Cost: $6,380 |
$7,344 | 110 | - | - | - | - | $290,290 | - | - | - | - | - |
$7,344 110 kWh |
- - kW-months/year |
- - MMBtu |
$290,290 - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.426 MODIFY WORKLOAD |
Savings: $47,807 Cost: $1,000 |
$10,682 | 160,000 | - | - | $37,125 | 3,750 | - | - | - | - | - | - |
$10,682 160,000 kWh |
- - kW-months/year |
$37,125 3,750 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $423,730 Cost: $9,380 |
$23,196 | 225,611 | $517 | 52 | $83,819 | 6,774 | $290,290 | - | $14,079 | - | $11,829 | - | $23,196 225,611 kWh |
$517 52 kW-months/year |
$83,819 6,774 MMBtu |
$290,290 - $ |
$14,079 - $ |
$11,829 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $106,053 Cost: $2,000 |
$15,852 | 225,501 | $517 | 52 | $63,776 | 6,442 | - | - | $14,079 | - | $11,829 | - | $15,852 225,501 kWh |
$517 52 kW-months/year |
$63,776 6,442 MMBtu |
- - $ |
$14,079 - $ |
$11,829 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Water Consumption |