Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Louisiana Tech |
---|---|
Assessment Year | 1987 |
Principal Product | PARBOILED RICE |
NAICS | n/a |
SIC | 2044 - Rice Milling |
Sales | $100,000,000-$500,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 10,000,000 Bushels |
Production Hrs. Annual | 8,400 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $938,287 | 19,803,928 | kWh | $0.05 |
Natural Gas | $511,634 | 181,346 | MMBtu | $2.82 |
Other Energy | $129,000 | 129,000 | MMBtu | $1.00 |
TOTAL ENERGY COSTS | $1,578,921 | |||
RECOMMENDED SAVINGS* | $263,380 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,080 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Electricity Usage | Natural Gas | Other Energy | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $40,000 Cost: $12,600 |
- | - | $40,000 | 14,200 | - | - | - | - |
- - kWh |
$40,000 14,200 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $109,000 Cost: $230,000 |
$410,000 | 10,300,117 | - | - | $(-301,000) | (-301,000) | - | - |
$410,000 10,300,117 kWh |
- - MMBtu |
$(-301,000) (-301,000) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $30,300 Cost: $20,000 |
$30,300 | - | - | - | - | - | - | - |
$30,300 - kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,780 Cost: $2,500 |
$1,780 | 44,549 | - | - | - | - | - | - |
$1,780 44,549 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2693 USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION |
Savings: $82,300 Cost: $217,000 |
$86,900 | 2,300,703 | - | - | - | - | $(-4,600) | - |
$86,900 2,300,703 kWh |
- - MMBtu |
- - MMBtu |
$(-4,600) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $263,380 Cost: $482,100 |
$528,980 | 12,645,369 | $40,000 | 14,200 | $(-301,000) | (-301,000) | $(-4,600) | - | $528,980 12,645,369 kWh |
$40,000 14,200 MMBtu |
$(-301,000) (-301,000) MMBtu |
$(-4,600) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,080 Cost: $35,100 |
$32,080 | 44,549 | $40,000 | 14,200 | - | - | - | - | $32,080 44,549 kWh |
$40,000 14,200 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Electricity Usage | Natural Gas | Other Energy | Administrative Changes |