Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1987
Principal Product FRUIT JUICES & VINEGAR
NAICS n/a
SIC 2037 - Frozen Fruits And Vegetables
Sales $100,000,000-$500,000,000
# of Employees 325
Plant Area (Sq.Ft.) 0
Annual Production 31,200,000 Pieces
Production Hrs. Annual 4,500
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $537,824 6,888,042 kWh $0.08
Natural Gas $22,365 7,573 MMBtu $2.95
Fuel Oil #6 $276,517 110,002 MMBtu $2.51
TOTAL ENERGY COSTS $836,706
RECOMMENDED SAVINGS* $48,181 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,034
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$25,545
Cost:
$1,275
- - $2,378 806 $29,407 11,716 $(-6,240) - -
-
kWh
$2,378
806
MMBtu
$29,407
11,716
MMBtu
$(-6,240)
-
$
02: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$4,668
Cost:
$4,050
- - $348 118 $4,320 1,721 - - -
-
kWh
$348
118
MMBtu
$4,320
1,721
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$6,707
Cost:
$24,000
- - $502 170 $6,205 2,472 - - -
-
kWh
$502
170
MMBtu
$6,205
2,472
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,453
Cost:
$3,862
$2,453 31,360 - - - - - - $2,453
31,360
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$470
Cost:
-
$470 - - - - - - - $470
-
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$5,019
Cost:
$15,000
- - $375 127 $4,644 1,850 - - -
-
kWh
$375
127
MMBtu
$4,644
1,850
MMBtu
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$3,319
Cost:
-
$3,319 42,497 - - - - - - $3,319
42,497
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$48,181
Cost:
$48,187
$6,242 73,857 $3,603 1,221 $44,576 17,759 $(-6,240) - $6,242
73,857
kWh
$3,603
1,221
MMBtu
$44,576
17,759
MMBtu
$(-6,240)
-
$
TOTAL IMPLEMENTED Savings:
$31,034
Cost:
$16,275
$470 - $2,753 933 $34,051 13,566 $(-6,240) - $470
-
kWh
$2,753
933
MMBtu
$34,051
13,566
MMBtu
$(-6,240)
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes Electricity Usage Natural Gas Fuel Oil #6 Administrative Changes