Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1998 |
Principal Product | Extruded/Molded PTFE |
NAICS | n/a |
SIC | 3053 - Gaskets, Packing And Sealing Devices |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 61,150 |
Annual Production | 1,500,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $178,387 | 2,667,644 | kWh | $0.07 |
Electricity Demand | $91,421 | 6,596 | kW-months/year | $13.86 |
LPG | $253,179 | 47,146 | MMBtu | $5.37 |
TOTAL ENERGY COSTS | $522,987 | |||
RECOMMENDED SAVINGS* | $177,045 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,498 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Electricity Usage | Electricity Demand | Electricity Fees | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $47,834 Cost: $5,100 |
$2,371 | 37,222 | - | - | - | - | $45,463 | 8,466 |
$2,371 37,222 kWh |
- - kW-months/year |
- - $ |
$45,463 8,466 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $53,137 Cost: $200,000 |
$27,492 | 431,125 | $35,666 | 2,592 | - | - | $(-10,021) | (-1,839) |
$27,492 431,125 kWh |
$35,666 2,592 kW-months/year |
- - $ |
$(-10,021) (-1,839) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $62,915 Cost: $200,000 |
$32,745 | 513,482 | $42,106 | 3,060 | - | - | $(-11,936) | (-2,190) |
$32,745 513,482 kWh |
$42,106 3,060 kW-months/year |
- - $ |
$(-11,936) (-2,190) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $3,174 Cost: $10,000 |
$4,956 | 77,960 | - | - | - | - | $(-1,782) | (-332) |
$4,956 77,960 kWh |
- - kW-months/year |
- - $ |
$(-1,782) (-332) MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,748 Cost: $2,019 |
- | - | - | - | - | - | $1,748 | 326 |
- - kWh |
- - kW-months/year |
- - $ |
$1,748 326 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,750 Cost: $17,906 |
$4,747 | 74,443 | $2,003 | 144 | - | - | - | - |
$4,747 74,443 kWh |
$2,003 144 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,487 Cost: $5,700 |
- | - | - | - | $1,487 | - | - | - |
- - kWh |
- - kW-months/year |
$1,487 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $177,045 Cost: $440,725 |
$72,311 | 1,134,232 | $79,775 | 5,796 | $1,487 | - | $23,472 | 4,431 | $72,311 1,134,232 kWh |
$79,775 5,796 kW-months/year |
$1,487 - $ |
$23,472 4,431 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,498 Cost: $19,925 |
$4,747 | 74,443 | $2,003 | 144 | - | - | $1,748 | 326 | $4,747 74,443 kWh |
$2,003 144 kW-months/year |
- - $ |
$1,748 326 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | LPG | Electricity Usage | Electricity Demand | Electricity Fees | LPG |