Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2006 |
Principal Product | Light conveyor belting |
NAICS | 326299 - All Other Rubber Product Manufacturing |
SIC | 3069 - Fabricated Rubber Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 127 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 1,300 Thousand Feet |
Production Hrs. Annual | 6,257 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $479,969 | 7,576,603 | kWh | $0.06 |
Electricity Demand | $107,506 | 20,595 | kW-months/year | $5.22 |
Electricity Fees | $3,000 | - | $ | - |
Natural Gas | $575,581 | 70,420 | MMBtu | $8.17 |
LPG | $7,244 | 45 | MMBtu | $160.98 |
Fuel Oil #4 | $202,741 | 25,128 | MMBtu | $8.07 |
TOTAL ENERGY COSTS | $1,376,041 | |||
RECOMMENDED SAVINGS* | $239,891 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $182,407 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #4 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $123,147 Cost: $15,525 |
- | - | - | - | $123,147 | 14,750 | - | - |
- - kWh |
- - kW-months/year |
$123,147 14,750 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $49,354 Cost: $121,835 |
$46,368 | 579,600 | $2,986 | 572 | - | - | - | - |
$46,368 579,600 kWh |
$2,986 572 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $40,484 Cost: $141,413 |
$(-2,016) | (-25,200) | - | - | $42,500 | 4,885 | - | - |
$(-2,016) (-25,200) kWh |
- - kW-months/year |
$42,500 4,885 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $11,241 Cost: $7,665 |
- | - | - | - | $6,201 | 696 | $5,040 | 359 |
- - kWh |
- - kW-months/year |
$6,201 696 MMBtu |
$5,040 359 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7314 REDUCE VENTILATION AIR |
Savings: $5,860 Cost: $3,505 |
$1,248 | 15,600 | - | - | $4,612 | 552 | - | - |
$1,248 15,600 kWh |
- - kW-months/year |
$4,612 552 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $4,046 Cost: - |
$4,046 | 50,576 | - | - | - | - | - | - |
$4,046 50,576 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,159 Cost: $5,681 |
- | - | - | - | $3,159 | 355 | - | - |
- - kWh |
- - kW-months/year |
$3,159 355 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $2,600 Cost: $500 |
$2,600 | 32,326 | - | - | - | - | - | - |
$2,600 32,326 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $239,891 Cost: $296,124 |
$52,246 | 652,902 | $2,986 | 572 | $179,619 | 21,238 | $5,040 | 359 | $52,246 652,902 kWh |
$2,986 572 kW-months/year |
$179,619 21,238 MMBtu |
$5,040 359 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $182,407 Cost: $140,865 |
$51,662 | 645,776 | $2,986 | 572 | $127,759 | 15,302 | - | - | $51,662 645,776 kWh |
$2,986 572 kW-months/year |
$127,759 15,302 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #4 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #4 |