Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2022
Principal Product Treated water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales $1,000,000-$5,000,000
# of Employees 8
Plant Area (Sq.Ft.) 25,000
Annual Production 1,000,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $205,954 1,031,800 kWh $0.20
Electricity Demand $57,973 2,560 kW-months/year $22.65
Electricity Fees $1,536 - $ -
Natural Gas $8,818 1,508 MMBtu $5.85
TOTAL ENERGY COSTS $274,281
RECOMMENDED SAVINGS* $80,298 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $27,047
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$50,962
Cost:
$247,937
$30,791 154,264 $6,251 276 $13,920 - $30,791
154,264
kWh
$6,251
276
kW-months/year
$13,920
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$19,685
Cost:
$11,100
$19,685 98,623 - - - - $19,685
98,623
kWh
-
-
kW-months/year
-
-
$
03: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$5,243
Cost:
$7,450
$4,541 22,750 $702 31 - - $4,541
22,750
kWh
$702
31
kW-months/year
-
-
$
04: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$2,289
Cost:
$900
$2,289 11,473 - - - - $2,289
11,473
kWh
-
-
kW-months/year
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,119
Cost:
$11,630
$1,032 5,171 $1,087 48 - - $1,032
5,171
kWh
$1,087
48
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$80,298
Cost:
$279,017
$58,338 292,281 $8,040 355 $13,920 - $58,338
292,281
kWh
$8,040
355
kW-months/year
$13,920
-
$
TOTAL IMPLEMENTED Savings:
$27,047
Cost:
$30,180
$25,258 126,544 $1,789 79 - - $25,258
126,544
kWh
$1,789
79
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $